To evaluate the efficiency of different methods of reading breast tomosynthesis (BT) image volumes.All viewing procedures consisted of free scroll volume browsing and three were combined with initial cine loops at three different frame rates (9, 14 and 25 fps). The presentation modes consisted of vertically and horizontally orientated BT image volumes. Fifty-five normal BT image volumes in mediolateral oblique view were collected. In these, simulated lesions were inserted, creating four unique image sets, one for each viewing procedure. Four observers interpreted the cases in a free-response task. Time efficiency, visual attention and search were investigated using eye tracking.Horizontally orientated BT image volumes were read faster than vertically when using free scroll browsing only and when combined with fast cine loop. Cine loops at slow frame rates were ruled out as inefficient.In general, horizontally oriented BT image volumes were read more efficiently. All viewing procedures except for slow frame rates were promising when assuming equivalent detection performance.
机译:为了评估使用不同方法读取乳房断层合成(BT)图像量的效率。所有观看过程均包括自由滚动体浏览,并且其中三个过程与初始电影循环以三种不同帧速率(9、14和25 fps)组合使用。演示模式由垂直和水平方向的BT图像体积组成。在中外侧斜视图中收集了55个正常BT图像体积。在这些模型中,插入了模拟的病灶,创建了四个独特的图像集,每个观看程序一个。四名观察员在无人响应的任务中解释了案件。仅使用自由滚动浏览并与快速电影循环结合使用时,通过眼动追踪研究了时间效率,视觉注意力和搜索。水平定向BT图像的读取速度比垂直方向要快。排除了慢帧速率下的电影循环效率低下的问题。通常,水平定向BT图像体积的读取效率更高。当假定等效的检测性能时,除慢帧速率外,所有观看程序都有望实现。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号