Image quality and radiation dose of low tube voltage 3rd generation dual-source coronary CT angiography in obese patients: A phantom study

机译:肥胖患者低管电压第三代双源冠状动脉CT血管造影的图像质量和辐射剂量:幻像研究

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: To assess the influence of tube potential on radiation dose and image quality of third-generation dual-source coronary CT angiography (CTA) in a phantom simulating an obese patient. Methods: A thoracic phantom was equipped with tubular inserts containing iodine solution and water. A soft-tissue-equivalent ring around the phantom simulated an obese patient. Images were acquired at tube potentials of 80, 100, 120 and 140 kV with second-generation dual-source CT (DSCT) and 70-150 kV (in 10-kV increments) with third-generation DSCT. Contrast-to-noise ratio (CNR) was calculated and CT dose index was recorded. Results: With second-generation DSCT, CNR was highest for 120 kV (19.0) and decreased with lower tube potential (12.0 at 80 kV) owing to disproportionately increased image noise. With third-generation DSCT, 70- and 80-kV acquisitions showed a smaller increase in noise. CNRs for third-generation DSCT were highest for 70 and 80 kV (21.1 and 21.2, respectively). Compared to 120 kV, radiation dose was 68 % and 49 % lower at 70 kV and 80 kV, respectively. Conclusion: Third-generation DSCT enables one to perform coronary CTA at 70-80 kV in obese patients without compromising CNR and thus reduces radiation dose by 49-68 %. Key points: ? Low tube potential CT angiography is currently not suitable for obese patients. ? Third-generation DSCT offers substantially increased tube power at low tube potential. ? This enables one to perform coronary CT angiography at 70-80 kV in obese patients. ? Signal-to-noise ratio is maintained owing to increased tube current. ? This approach can be expected to reduce radiation dose by 49-68 %.
机译:目的:在模拟肥胖患者的幻象中,评估管电势对第三代双源冠状动脉CT血管造影(CTA)的辐射剂量和图像质量的影响。方法:胸模上装有装有碘溶液和水的管状插入物。幻影周围的软组织等效环模拟了肥胖患者。使用第二代双源CT(DSCT)在80、100、120和140 kV的管电势下采集图像,而使用第三代DSCT在70-150 kV(以10 kV的增量)下采集图像。计算对比噪声比(CNR),并记录CT剂量指数。结果:第二代DSCT的CNR最高为120 kV(19.0),而由于较低的电子管电位(80 kV时为12.0),CNR降低,原因是图像噪声成比例增加。使用第三代DSCT,70 kV和80 kV采集的噪声增加较小。第三代DSCT的CNR最高为70 kV和80 kV(分别为21.1和21.2)。与120 kV相比,在70 kV和80 kV时,辐射剂量分别降低68%和49%。结论:第三代DSCT使肥胖患者能够在70-80 kV的电压下执行冠状动脉CTA,而不会损害CNR,因此可将放射剂量降低49-68%。关键点: ?低管电位CT血管造影术目前不适合肥胖患者。 ?第三代DSCT在低电子管电势下可显着提高电子管功率。 ?这使肥胖患者能够在70-80 kV下进行冠状动脉CT血管造影。 ?由于管电流的增加,信噪比得以保持。 ?可以预期这种方法可以减少49-68%的辐射剂量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号