首页> 外文期刊>European journal of applied physiology >Reproducibility of the blood lactate threshold, 4 mmol.l(-1) marker, heart rate and ratings of perceived exertion during incremental treadmill exercise in humans.
【24h】

Reproducibility of the blood lactate threshold, 4 mmol.l(-1) marker, heart rate and ratings of perceived exertion during incremental treadmill exercise in humans.

机译:血液乳酸阈值,4 mmol.l(-1)标记,心率和人类在递增式跑步机运动期间的感知劳累等级的可重复性。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to investigate the reproducibility of blood lactate measurements, heart rate (HR) and ratings of perceived exertion (RPE) during treadmill exercise at speeds corresponding to the lactate threshold ( v(Th,la)-) and a fixed blood lactate concentration of 4 mmol.l(-1)( v(la)-(,4)). Possible differences in reproducibility related to fitness levels were also investigated. A group of 20 men [mean (SD)] [age 20.5 (1.4) years] and 16 women [age 21.2 (0.9) years] took part in the study. The subjects performed two identical incremental exercise tests consisting of at least six 4 min stages. Blood lactate concentrations, HR and RPE were recorded at the end of each stage. Limits of agreement (LoA), correlation coefficients and 95% confidence intervals for the mean difference between tests were employed to investigate the level of agreement and reproducibility of blood lactate concentration, HR and RPE. For the group as a whole, the sample correlation coefficient for speed at v(Th,la)- wasr=0.88, and was r=0.92 for the speed at v(la)-(,4). At v(Th,la) -, the correlation coefficients for the moderately fit and unfit were r=0.94 and r=0.36, respectively, and at v(la)-(,4) r=0.93 and r=0.68, respectively. The LoA for the moderately fit group indicated that a change of 1.62 km.h(-1) in v(Th,la)- would be necessary to be considered a change in training status. For HR and RPE, relationships between the tests were generally poor. The LoA suggested that changes in scores must be unacceptably large. These findings cast doubt on the sensitivity of testing for change of blood lactate concentration, HR and RPE in this population.
机译:这项研究的目的是研究在跑步机上以对应于乳酸阈值(v(Th,la)-)和固定速度的速度进行运动时血液乳酸测量值,心率(HR)和感知劳累(RPE)等级的可重复性血乳酸浓度为4 mmol.l(-1)(v(la)-(,4))。还研究了与适应性水平相关的可重复性的可能差异。一组20名男性[平均(SD)] [年龄20.5(1.4)岁]和16名女性[年龄21.2(0.9)岁]参加了该研究。受试者进行了两个相同的增量运动测试,包括至少六个4分钟的阶段。在每个阶段结束时记录血乳酸浓度,HR和RPE。检验的平均差异之间的一致性极限(LoA),相关系数和95%置信区间用于研究血液乳酸浓度,HR和RPE的一致性水平和可重复性。对于整个组,v(Th,la)-处的速度的样本相关系数为wasr = 0.88,v(la)-(,4)处的速度的样本相关系数为r = 0.92。在v(Th,la)-时,适度拟合和不拟合的相关系数分别为r = 0.94和r = 0.36,在v(la)-(,4)时r = 0.93和r = 0.68。中度适应人群的LoA表明,v(Th,la)-的1.62 km.h(-1)的变化将被认为是训练状态的变化。对于HR和RPE,测试之间的关系通常较差。协议书建议分数变化必须大得无法接受。这些发现使人们对该人群中血乳酸浓度,HR和RPE变化的检测敏感性感到怀疑。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号