pH-Mediated field-amplified sample stacking of pharmaceutical cations in high-ionic strength samples

机译:pH值介导的高离子强度样品中药物阳离子的现场放大样品堆叠

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Capillary electrophoretic separation of samples of physiological origin typically have both poor resolution and efficiency due to destacking. We have previously reported a stacking method for concentration of catecholamines in artificial dialysate, or Ringer's solution. However, pH-mediated sample stacking of other cations has not been investigated. In this report, pH-mediated stacking has been extended to eletripan, dofetilide, doxazosin, sildenafil, UK-103,320, UK-202,581, and CP-122,288. These compounds were chosen without prior structural screening except that they were cationic at the pH of our background electrolyte (BGE). Capillary electrophoretic behavior of samples in BGE is compared with those of samples in Ringer's solution with and without pl-l-mediated acid stacking. Results indicate that the peak heights and efficiencies for acid-stacked samples are increased compared to the unstacked samples in Ringer's solution or BGE. For example, the peak efficiencies for 5 s injections of eletriptan in BGE and Ringer's solution are 138 000 and 72000 plates, respectively. In contrast, a 10 s injection of eletriptan followed by acid injection for 16 s produces a peak with 246 000 plates. Evaluation of the stacking effect was performed by comparison of the peak height at similar peak efficiencies for samples in Ringer's solution with and without stacking. Using this method, pH-mediated acid stacking provides a 10- to 27-fold sensitivity enhancement for the seven cations. [References: 24]
机译:生理来源的样品进行毛细管电泳分离通常会由于拆垛而导致分离度和效率低下。先前我们已经报道了一种在人工透析液或林格氏溶液中浓缩儿茶酚胺的堆积方法。但是,尚未研究pH介导的其他阳离子的样品堆积。在此报告中,pH介导的堆叠扩展到了伊曲坦,多非利特,多沙唑嗪,西地那非,UK-103,320,UK-202,581和CP-122,288。选择这些化合物时无需事先进行结构筛选,只是它们在我们本底电解质(BGE)的pH值上是阳离子。比较了在有和没有pl-1介导的酸堆积的情况下,BGE中样品的毛细管电泳行为与林格溶液中样品的毛细管电泳行为。结果表明,与林格溶液或BGE中的未堆叠样品相比,酸堆叠样品的峰高和效率均得到了提高。例如,在BGE和林格氏液中注射伊曲肽5 s的最高效率分别为138 000和72000板。相反,依曲曲坦注射10 s,然后酸注射16 s,产生的峰为246 000个板。通过比较在有和没有堆积的林格氏溶液中样品在相似峰效率下的峰高,来评估堆积效果。使用这种方法,pH介导的酸堆积对七个阳离子的灵敏度提高了10到27倍。 [参考:24]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号