首页> 外文期刊>International Journal of Dentistry >Influence of Immediate Dentin Sealing on the Shear Bond Strength of Pressed Ceramic Luted to Dentin with Self-Etch Resin Cement
【24h】

Influence of Immediate Dentin Sealing on the Shear Bond Strength of Pressed Ceramic Luted to Dentin with Self-Etch Resin Cement

机译:即时牙本质密封对自蚀树脂水泥挤压陶瓷对牙本质的剪切粘结强度的影响

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

Objectives. To examine the effect of immediate dentin sealing (IDS), with dentin bonding agents (DBAs) applied to freshly cut dentin, on the shear bond strength of etched pressed ceramic luted to dentin with RelyX Unicem (RXU) cement. Method. Eighty extracted noncarious third molars were ground flat to expose the occlusal dentin surfaces. The teeth were randomly allocated to five groups (A to E) of sixteen teeth each. Groups A to D were allocated a dentin bonding agent (Optibond FL, One Coat Bond, Single Bond, or Go!) that was applied to the dentin surface to mimic the clinical procedure of IDS. These specimen groups then had etched glass ceramic discs (Authentic) luted to the sealed dentin surface using RXU. Group E (control) had etched glass ceramic discs luted to the dentin surface (without a dentin bonding agent) using RXU following the manufacturer's instructions. All specimens were stored for one week in distilled water at room temperature and then shear stressed at a constant cross-head speed of 1 mm per minute until failure. Statistical analysis was performed by ANOVA followed by post hoc Tukey HSD method (P < 0.05) applied for multiple paired comparisons. Results. The shear bond strength results for group A to E ranged from 6.94+- 1.53 to 10.03 +- 3.50 MPa. One-way ANOVA demonstrated a difference (P < 0.05) between the groups tested and the Tukey HSD demonstrated a significant (P < 0.05) difference between the shear bond strength (SBS) of Optibond FL (Group A) and Go! (Group D). There was no statistical difference (P > 0.05) in the SBS between the test groups (A-D) or the control (group E). Conclusion. IDS using the dentin bonding agents tested does not statistically (P > 0.05) affect the shear bond strength of etched pressed ceramic luted to dentin with RXU when compared to the control.
机译:目标。若要检查立即使用牙本质粘合剂(DBA)应用于刚切下的牙本质的牙本质密封(IDS)对使用RelyX Unicem(RXU)水泥将浸蚀后的牙本质粘合到牙本质上的蚀刻陶瓷的剪切粘合强度的影响。方法。将80个提取的非龋齿第三磨牙磨平,以暴露牙合牙本质表面。牙齿被随机分配给五组(A至E),每组十六个牙齿。给A至D组分配牙本质粘合剂(Optibond FL,One Coat Bond,Single Bond或Go!),将其应用于牙本质表面以模拟IDS的临床过程。然后,这些样本组已使用RXU将蚀刻过的玻璃陶瓷圆片(Authentic)浸入密封的牙本质表面。 E组(对照组)使用RXU按照制造商的说明将蚀刻的玻璃陶瓷圆盘浸入牙本质表面(无牙本质结合剂)。将所有样品在室温下的蒸馏水中保存一周,然后以每分钟1毫米的恒定十字头速度剪切应力直至失效。通过ANOVA进行统计学分析,然后应用多对配对比较的事后Tukey HSD方法(P <0.05)。结果。 A至E组的剪切粘结强度结果为6.94±1.53至10.03±3.50MPa。单向方差分析表明测试组之间存在差异(P <0.05),Tukey HSD表明Optibond FL(A组)和Go!的抗剪强度(SBS)之间存在显着差异(P <0.05)。 (D组)。试验组(A-D)或对照组(E组)之间的SBS没有统计学差异(P> 0.05)。结论。与对照组相比,使用测试的牙本质粘合剂的IDS不会统计学(P> 0.05)影响使用RXU浸蚀到牙本质的经压制的蚀刻陶瓷的剪切粘合强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号