首页> 外文期刊>International Journal of Thermophysics >Size-of-Source Effect Difference Between Direct and Indirect Methods of Radiation Thermometers
【24h】

Size-of-Source Effect Difference Between Direct and Indirect Methods of Radiation Thermometers

机译:直接和间接辐射温度计方法之间的源大小效应差异

获取原文
获取原文并翻译 | 示例

摘要

The size-of-source effect (SSE) of radiation thermometers is generally determined using direct and indirect methods. The present paper describes the difference in the SSE obtained using the two methods. Three thermometers at different SSE levels, namely, 1.5 × 10~(-4), 1.05 × 10~(-3), and 2.44 × 10~(-3), are selected. SSEs with 5 mm to 96 mm aperture diameters are higher in the indirect than in the direct method. Three factors contribute to this difference: the light reflection from the inside face and edge of the aperture to the black spot, the relay reflections from the thermometer and background, and the decreased radiance caused by obstruction of light by a black spot. Thus, the difference in the SSEs results from the difference in the principle of the two methods and not from the SSE levels of the thermometers themselves. The difference is negligible to be considered in a number of radiation thermometers, but they must be taken into consideration in top-level intercomparisons.
机译:通常使用直接和间接方法确定辐射温度计的源尺寸效应(SSE)。本文介绍了使用两种方法获得的SSE的差异。选择三种SSE级别不同的温度计,分别为1.5×10〜(-4),1.05×10〜(-3)和2.44×10〜(-3)。间接法比直接法的孔径直径在5mm至96mm的SSE高。造成这种差异的因素有三个:从光圈内表面和边缘到黑点的光反射,从温度计和背景发出的中继反射,以及由黑点遮挡光导致的辐射降低。因此,SSE的差异是由两种方法原理的差异引起的,而不是温度计本身的SSE水平引起的。在许多辐射温度计中可以忽略不计这种差异,但是在顶级比对中必须考虑它们。