Feasibility of fully automated detection of fiducial markers implanted into the prostate using electronic portal imaging: A comparison of methods.

机译:使用电子门静脉成像全自动检测植入前列腺的基准标记的可行性:方法比较。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Purpose: To investigate the feasibility of fully automated detection of fiducial markers implanted into the prostate using portal images acquired with an electronic portal imaging device. Methods and Materials: We have made a direct comparison of 4 different methods (2 template matching-based methods, a method incorporating attenuation and constellation analyses and a cross correlation method) that have been published in the literature for the automatic detection of fiducial markers. The cross-correlation technique requires a-priory information from the portal images, therefore the technique is not fully automated for the first treatment fraction. Images of 7 patients implanted with gold fiducial markers (8 mm in length and 1 mm in diameter) were acquired before treatment (set-up images) and during treatment (movie images) using 1MU and 15MU per image respectively. Images included: 75 anterior (AP) and 69 lateral (LAT) set-up images and 51 AP and 83 LAT movie images. Using the different methods described in the literature, marker positions were automatically identified. Results: The method based upon cross correlation techniques gave the highest percentage detection success rate of 99% (AP) and 83% (LAT) set-up (1MU) images. The methods gave detection success rates of less than 91% (AP) and 42% (LAT) set-up images. The amount of a-priory information used and how it affects the way the techniques are implemented, is discussed. Conclusions: Fully automated marker detection in set-up images for the first treatment fraction is unachievable using these methods and that using cross-correlation is the best technique for automatic detection on subsequent radiotherapy treatment fractions.
机译:目的:研究使用通过电子门禁成像设备获取的门禁图像对植入前列腺的基准标记进行全自动检测的可行性。方法和材料:我们直接比较了4种不同的方法(2种基于模板匹配的方法,结合了衰减和星座分析的方法以及互相关方法),这些方法已在文献中发表,用于自动检测基准标记。互相关技术需要来自门户图像的先验信息,因此对于第一个治疗分数该技术不是完全自动化的。在治疗前(设置图像)和治疗期间(电影图像)分别获得每幅图像1MU和15MU的7例植入金基准标记的患者的图像(长8 mm,直径1 mm)。图像包括:75个前(AP)和69个侧面(LAT)设置图像以及51个AP和83个LAT电影图像。使用文献中描述的不同方法,可以自动识别标记位置。结果:基于互相关技术的方法提供了99%(AP)和83%(LAT)设置(1MU)图像的最高百分比检测成功率。这些方法的检测成功率分别小于91%(AP)和42%(LAT)设置图像。讨论了所使用的先验信息的数量以及它如何影响技术的实现方式。结论:使用这些方法无法在第一个治疗部位的设置图像中实现全自动标记检测,而使用互相关是自动检测后续放射疗法治疗部位的最佳技术。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号