首页> 外文期刊>International journal of hyperthermia: The official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group >Electrical-thermal performance of a cooled RF applicator for hepatic ablation with additional distant infusion of hypertonic saline: In vivo study and preliminary computer modeling
【24h】

Electrical-thermal performance of a cooled RF applicator for hepatic ablation with additional distant infusion of hypertonic saline: In vivo study and preliminary computer modeling

机译:射频消融的射频冷却器的电热性能,以及远距离输注高渗盐水的体内研究和初步计算机建模

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: The Cool-tip electrode is one of the most widely employed applicators in radiofrequency (RF) hepatic ablation. Previous research demonstrated that it is possible to enlarge coagulation volume when the single cooled electrode is associated with distant infusion of saline (hybrid applicator). The aim of this study was to compare the electrical-thermal behaviour of the Cool-tip electrode with that of the hybrid applicator. Materials and methods: Forty-two RF ablations were performed on a total of 10 pigs: 22 with the Cool-tip electrode and 20 with the hybrid applicator (low infused saline volumetric flow rate of 6mL/h at 2mm distance). We compared both electrical performance (delivered power and number of roll-offs, i.e. sudden rises in impedance that interrupt the power delivery) and coagulation zone characteristics. In addition, we built a one-dimensional model to provide a basic physical explanation of the difference in performance between the different applicators. Results: The experimental results showed that the number of roll-offs with the Cool-tip electrode was higher (24.3±3.1 versus 6.7±7.0). The hybrid applicator created larger coagulation volumes (19.7±9.5 cm versus 9.5±5.8 cm) with larger transverse diameters (2.5±0.6 versus 1.9±0.5cm). The one-dimensional model confirmed the delay in the incidence of the first roll-off, but not the heterogeneity of the hybrid applicator's electrical performance in the experiments. Conclusions: The hybrid applicator produces fewer roll-off episodes than the Cool-tip electrode and creates larger coagulation volumes with larger transverse diameters.
机译:目的:冷尖电极是射频(RF)肝消融术中使用最广泛的涂药器之一。先前的研究表明,当单个冷却电极与远距离注入盐水(混合施药器)相关联时,有可能增大凝血体积。这项研究的目的是比较冷尖电极与混合式涂药器的电热行为。材料和方法:总共对10头猪进行了42次射频消融:使用冷尖电极22头,使用混合式涂药器20头(在2mm距离处的低注入盐水体积流量为6mL / h)。我们比较了电性能(输送功率和滚降次数,即阻抗的突然升高中断了输送功率)和凝结区特性。此外,我们建立了一个一维模型,以提供有关不同施药器之间性能差异的基本物理解释。结果:实验结果表明,冷尖电极的滚降次数更高(24.3±3.1对6.7±7.0)。混合式涂药器产生了较大的凝结体积(19.7±9.5 cm对9.5±5.8 cm),横向直径较大(2.5±0.6对1.9±0.5cm)。一维模型证实了第一次降落发生的延迟,但没有证实混合施药器在电气性能方面的异质性。结论:混合式涂药器产生的滚落次数少于冷尖电极,并产生较大的凝结体积和较大的横向直径。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号