...
首页> 外文期刊>International Journal of Biomedical Science >Comparison of Two Methods for the Determination of the Effects of Ionizing Radiation on Blood Cell Counts in Mice
【24h】

Comparison of Two Methods for the Determination of the Effects of Ionizing Radiation on Blood Cell Counts in Mice

机译:两种测定电离辐射对小鼠血细胞计数影响的方法的比较

获取原文
获取原文并翻译 | 示例

摘要

A reliable technique is needed to determine the effect of ionizing radiation on white blood cell (WBC) counts. Facilities that utilize automated methods can provide this service. However, utilizing external facilities can introduce additional variables, such as differences between time of sample collection and time of sample processing; which may affect the results. The purpose of the present study was to determine whether an automated method at an external facility can accurately determine radiation-induced changes in total WBC, lymphocyte and granulocyte counts when samples are analyzed at periods of time up to 24 hours after collection and stored either at room temperature or at 4℃. To accomplish this, we compared automated blood cell counts determined at an external facility with our manual blood cell counts processed immediately after sample collection or 24 h after sample collection and stored either at room temperature or 4℃ from mice exposed to 2 Gy proton or 2 Gy gamma radiation. Our results show a close correlation and good agreement between the two methods, indicating that neither a delay of 24 hours in sample processing nor storage temperature affected white blood cell counts. Analysis of the effects of radiation on blood cell counts by either manual or automated cell counts revealed a statistically significant decrease in lymphocyte and granulocyte counts at different days post-irradiation, with no statistically significant difference between the methods employed; therefore both manual and automated blood cell counts are reliable methods to determine the effects of ionizing radiation in blood cells.
机译:需要一种可靠的技术来确定电离辐射对白细胞(WBC)计数的影响。利用自动化方法的设施可以提供此服务。但是,利用外部设施可能会引入其他变量,例如样品采集时间与样品处理时间之间的差异;这可能会影响结果。本研究的目的是确定当在采集后长达24小时的时间内对样品进行分析并保存在以下位置时,外部设施的自动化方法是否可以准确确定辐射引起的总WBC,淋巴细胞和粒细胞计数的变化:室温或4℃。为此,我们将外部设施确定的自动血细胞计数与样本采集后或样本采集后24小时立即处理并在室温或4℃下暴露于2 Gy质子或2 Gy小鼠的人工血细胞计数进行了比较。 Gy伽玛射线。我们的结果表明两种方法之间的密切相关性和良好一致性,表明样品处理中的24小时延迟和存储温度均不会影响白细胞计数。通过手动或自动细胞计数分析放射线对血细胞计数的影响,发现在辐照后的不同天淋巴细胞和粒细胞计数有统计上的显着下降,所用方法之间无统计学上的显着差异。因此,手动和自动血细胞计数都是确定血细胞中电离辐射影响的可靠方法。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号