...
首页> 外文期刊>International Journal of Adhesion & Adhesives >Effect of acidic monomer concentration on the dentin bond stability of self-etch adhesives
【24h】

Effect of acidic monomer concentration on the dentin bond stability of self-etch adhesives

机译:酸性单体浓度对自蚀胶牙本质键稳定性的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

This study evaluated the effect of the concentration of acidic functional monomer on the dentin bond stability of a model two-step, self-etch adhesive system. Six self-etch primers were formulated using hydroxyethyl methacrylate (HEMA), 1,3-glycerol dimethacrylate phosphate (GDMA-P), ethanol and water. Different mass concentrations of GDMA-P were tested: 0,15, 30,50, 70 or 100% (primers labeled P_(0-100)). The pH of the solutions was measured. The bonding resin was composed of (di)methacrylates. Bond strength to bovine dentin was assessed through a microtensile bond test. The beam specimens were stored in distilled water, at 37 °C, for 24 h, 6 months or 1 year. Data were statistically analyzed and failure modes classified under magnification. The increase in acidic monomer concentration was associated with an exponential decrease in pH (R~2=0.999; P< 0.001). All specimens debonded prematurely for the primers P0, P_(70) and P_(100). After 24 h, the bond strengths for P_(50)>P_(30)=P_(15). After 6 months and 1 year, P_(50)=P_(30) > P_(15). The bond strength after 6 months was similar to 24 h for P_(15) and P_(50), but significantly lower after 1 year. P_(30) showed no differences in bond strength over the 1-year storage period. A predominance of mixed failures was detected for all primers at 24 h. After 6 months, P_(30) and P_(50) showed a predominance of adhesive failures. After 1 year, the predominant failure mode for all primers was cohesive within dentin. In conclusion, a mass fraction of 50% of phosphate monomer is a limit to be added to self-etch primers; a more stable longevity of the bonds was obtained with the primer with 30% of phosphate methacrylate.
机译:这项研究评估了酸性功能单体的浓度对模型两步式自蚀刻胶粘剂系统的牙本质键稳定性的影响。使用甲基丙烯酸羟乙酯(HEMA),磷酸1,3-甘油二甲基丙烯酸酯(GDMA-P),乙醇和水配制了六种自蚀底漆。测试了不同质量浓度的GDMA-P:0.15%,30.50%,70%或100%(标记为P_(0-100)的引物)。测量溶液的pH。粘结树脂由(二)甲基丙烯酸酯组成。通过微拉伸粘合试验评估对牛牙本质的粘合强度。将梁样品在37°C的蒸馏水中保存24小时,6个月或1年。对数据进行统计分析,并根据放大率对失效模式进行分类。酸性单体浓度的增加与pH值的指数下降有关(R〜2 = 0.999; P <0.001)。对于底漆P0,P_(70)和P_(100),所有样品都过早脱胶。 24小时后,P_(50)> P_(30)= P_(15)的粘结强度。在6个月零一年后,P_(50)= P_(30)> P_(15)。 P_(15)和P_(50)在6个月后的粘合强度类似于24小时,但1年后显着降低。 P_(30)在1年的储存期中没有显示出粘结强度的差异。在24 h时,所有引物的混合故障占优势。 6个月后,P_(30)和P_(50)表现出大部分的粘合失败。一年后,所有引物的主要失效模式是牙本质内聚。总之,磷酸盐单体的质量分数为50%是要添加到自蚀刻底漆中的限制;用含有30%的甲基丙烯酸磷酸酯的底漆可获得更长的稳定键寿命。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号