首页> 美国卫生研究院文献>Springer Open Choice >The effect of Er:YAG laser irradiation on the bond stability of self-etch adhesives at different dentin depths
【2h】

The effect of Er:YAG laser irradiation on the bond stability of self-etch adhesives at different dentin depths

机译:Er:YAG激光辐照对不同牙本质深度自蚀胶黏剂结合稳定性的影响

代理获取
本网站仅为用户提供外文OA文献查询和代理获取服务,本网站没有原文。下单后我们将采用程序或人工为您竭诚获取高质量的原文,但由于OA文献来源多样且变更频繁,仍可能出现获取不到、文献不完整或与标题不符等情况,如果获取不到我们将提供退款服务。请知悉。

摘要

The aim of this study was to evaluate the effect of Er:YAG laser irradiation on the micro-shear bond strength of self-etch adhesives to the superficial dentin and the deep dentin before and after thermocycling. Superficial dentin and deep dentin surfaces were prepared by flattening of the occlusal surfaces of extracted human third molars. The deep or superficial dentin specimens were randomized into three groups according to the following surface treatments: group I (control group), group II (Er:YAG laser; 1.2 W), and group III (Er:YAG laser; 0.5 W). Clearfil SE Bond or Clearfil S3 Bond was applied to each group’s dentin surfaces. After construction of the composite blocks on the dentin surface, the micro-shear bond testing of each adhesive was performed at 24 h or after 15,000 thermal cycles. The data were analyzed using a univariate analysis of variance and Tukey’s test (p < 0.05). Laser irradiation in superficial dentin did not significantly affect bond strength after thermocycling (p > 0.05). However, deep-dentin specimens irradiated with laser showed significantly higher bond strengths than did control specimens after thermocycling (p < 0.05). Thermocycling led to significant deterioration in the bond strengths of all deep-dentin groups. The stable bond strength after thermocycling was measured for all of the superficial-dentin groups. No significant difference was found between the 0.5 and 1.2 W output power settings. In conclusion, the effect of laser irradiation on the bond strength of self-etch adhesives may be altered by the dentin depth. Regardless of the applied surface treatment, deep dentin showed significant bond degradation.
机译:这项研究的目的是评估热循环前后Er:YAG激光辐照对自蚀刻胶粘剂与浅层牙本质和深层牙本质的微剪切粘结强度的影响。通过使提取的人第三磨牙的咬合面变平来制备浅层牙本质和深层牙本质表面。根据以下表面处理,将深层或浅层的牙本质标本随机分为三组:第一组(对照组),第二组(Er:YAG激光; 1.2W)和第三组(Er:YAG激光; 0.5W)。将Clearfil SE Bond或Clearfil S 3 Bond应用于每个组的牙本质表面。在牙本质表面上构建了复合材料块之后,在24小时或15,000个热循环后对每种粘合剂进行微剪切粘结测试。使用单变量方差分析和Tukey检验(p <0.05)对数据进行了分析。浅层牙本质中的激光照射对热循环后的粘合强度没有显着影响(p> 0.05)。但是,在热循环后,用激光辐照的深牙本质样品显示出比对照样品明显更高的结合强度(p <0.05)。热循环导致所有深牙本质基团的结合强度显着下降。测量了所有表层-牙本质基团在热循环后的稳定结合强度。在0.5和1.2 W输出功率设置之间没有发现显着差异。总之,激光照射对自蚀刻胶粘剂粘结强度的影响可能会因牙本质深度而改变。无论采用何种表面处理,深牙本质均显示出明显的键降解。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
代理获取

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号