首页> 外文期刊>Arthroscopy: the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association >Dynamic Evaluation of Pivot-Shift Phenomenon in Double-Bundle Anterior Cruciate Ligament Reconstruction Using Triaxial Accelerometer
【24h】

Dynamic Evaluation of Pivot-Shift Phenomenon in Double-Bundle Anterior Cruciate Ligament Reconstruction Using Triaxial Accelerometer

机译:使用三轴加速度计动态评估双束前交叉韧带重建中的轴心位移现象

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To evaluate the effect of initial graft tension on rotational stability and to determine the minimum required tension (MRT) based on the pivot-shift phenomenon in isolated anteromedial bundle (AMB), isolated posteromedial bundle (PLB), and double-bundle anterior cruciate ligament (ACL) reconstructions using a triaxial accelerometer during surgery. Methods: Primary double-bundle ACL reconstructions were included. The pivot-shift test and N-test were performed before and during surgery with the acceleration measurements using a triaxial accelerometer. The pivot-shift test was also manually graded. The AMB and PLB were fixed to a graft tensioning system during surgery with the following settings: (1) AMB only (AMB), (2) PLB only (PLB), and (3) AMB and PLB (A+P). The total graft tension was first set at 20 N and then was increased in increments of 10 N until the pivot-shift test became negative, which was defined as the MRT in each setting. Results: Twenty-five patients were evaluated. The MRT in the AMB setting averaged 26 N (range, 20 to 40 N); in the PLB setting, 28 N (range, 20 to 40 N); and in the A+P setting, 24 N (range, 20 to 40 N). The MRT in the A+P setting was significantly smaller than that in the PLB setting (P =.008). The acceleration in the A+P setting was significantly smaller than that in the AMB and PLB settings both in the pivot-shift test (vs AMB: P = .007, vs PLB: P = .011) and in the N-test (vs AMB: P < .001, vs PLB: P < .001). Conclusions: Double-bundle ACL reconstruction better controlled rotational stability with smaller MRT than isolated PLB reconstruction at the time of surgery. In double-bundle reconstruction, the MRT based on the pivot-shift phenomenon could be larger than previously reported MRT based on anteroposterior laxity.
机译:目的:评估初始移植物张力对旋转稳定性的影响,并基于孤立的前内侧束(AMB),孤立的后内侧束(PLB)和双束前束中的枢转移位现象确定最小所需张力(MRT)手术期间使用三轴加速度计重建十字韧带(ACL)。方法:包括原发性双束ACL重建。枢轴位移测试和N检验在手术之前和期间进行,并使用三轴加速度计进行加速度测量。轴移测试也已手动分级。手术期间将AMB和PLB固定在移植物张紧系统上,并具有以下设置:(1)仅AMB(AMB),(2)仅PLB(PLB)和(3)AMB和PLB(A + P)。首先将总移植物张力设置为20 N,然后以10 N的增量增加,直到枢轴位移测试变为负值,这被定义为每种设置中的MRT。结果:评估了25例患者。 AMB设置中的MRT平均为26 N(范围为20到40 N);在PLB设置中为28 N(范围为20到40 N);在A + P设置中为24 N(范围为20到40 N)。 A + P设置中的MRT显着小于PLB设置中的MRT(P = .008)。在轴移测试(vs AMB:P = .007,vs PLB:P = .011)和N检验(A + P)中的加速度明显小于AMB和PLB设置中的加速度vs AMB:P <.001,vs PLB:P <.001)。结论:与手术时分离的PLB重建相比,双束ACL重建可更好地控制旋转稳定性,而MRT较小。在双束重建中,基于枢轴移位现象的MRT可能比先前报道的基于前后松弛的MRT更大。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号