Primary stability of osteochondral grafts used in mosaicplasty.

机译:用于镶嵌成形术的骨软骨移植物的主要稳定性。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: The goal of our experiments was to determine the primary stability of osteochondral grafts used in mosaicplasty. The effect of graft diameter and dilation, as well as multiple grafting, were studied in a porcine model. METHODS: Single osteochondral grafts, 4.5 and 6.5 mm in diameter, and multiple grafts were transplanted from the trochlea of porcine femurs to the weight-bearing area of the lateral femoral condyle. In the multiple grafting series, 3 grafts 4.5 mm in diameter were transplanted either in a row or in circular fashion. The grafts were first pushed in level with the surrounding cartilage surface, then they were pushed 3 mm below cartilage level. The push-in forces were measured. The effect of graft diameter and the extent of dilation on primary stability were studied as well as the influence of multiple grafting. RESULTS: In the case of 4.5-mm grafts, the mean level push-in force was 43.5 N, and pushing 3 mm below cartilage level required a mean of 92.5 N (n = 13). In the case of 6.5-mm grafts, level push-in required a mean of 76.2 N, and for pushing 3 mm below cartilage level a mean of 122.2 N force had to be used (n = 14). The length of the drill hole and the dilation were both 20 mm in each setting. When using 20-mm long drill holes and 15-mm dilation length, the values above were found to be 36.6 N and 122.5 N in the case of 4.5-mm grafts (n = 12). Mean level push-in force in the first (row) multiple series was 31.8 N, and pushing 3 mm below cartilage level required a mean of 52.17 N (n = 7). In the second series (circle), level push-in required a mean of 30.44 N, and for pushing 3-mm below cartilage level a mean of 54.33 N force had to be used (n = 9). In the control series (1 single graft) the mean level push-in force was 38.7 N, and pushing 3 mm deeper required a mean of 86.8 N (n = 9). CONCLUSIONS: These results suggest that grafts of greater diameter are more stable in absolute values and stability may be increased by shorter dilation length, whereas level push-in forces do not increase significantly. There is no difference in primary stability between grafts implanted in a row or in circular fashion, and multiple grafts may not be as stable as single grafts in the initial period after transplantation. CLINICAL RELEVANCE: This is a randomized, controlled in vitro animal trial that helps us to better understand the primary stability of osteochondral grafts and to refine surgical techniques as well as postoperative protocols.
机译:目的:我们的实验目的是确定用于镶嵌成形术的骨软骨移植物的主要稳定性。在猪模型中研究了移植物直径和扩张以及多次移植的影响。方法:将单股骨软骨移植物(直径分别为4.5和6.5 mm)和多股移植物从猪股骨的滑车移植到股骨外侧con的承重区域。在多次嫁接系列中,将3根直径4.5 mm的嫁接成行或圆形移植。首先将移植物推入与周围软骨表面齐平的位置,然后将其推入低于软骨水平3 mm的位置。测量了推入力。研究了接枝直径和扩张程度对一次稳定性的影响,以及多次接枝的影响。结果:对于4.5毫米的移植物,平均推入力为43.5 N,而向软骨水平以下推入3 mm则需要平均92.5 N(n = 13)。对于6.5毫米的移植物,水平推入需要平均76.2 N,而要在软骨水平以下推入3 mm,则必须使用平均122.2 N的力(n = 14)。在每种设置下,钻孔的长度和膨胀均为20 mm。当使用20毫米长的钻孔和15毫米扩张长度时,对于4.5毫米移植物(n = 12),上述值分别为36.6 N和122.5N。在第一个(行)多重序列中,平均水平推入力为31.8 N,而向软骨水平下推3 mm需要平均52.17 N(n = 7)。在第二个系列(圆形)中,水平推入平均需要30.44 N,而要在软骨水平以下推入3-mm,则必须使用平均54.33 N的力(n = 9)。在对照系列中(1个单移植物),平均水平推入力为38.7 N,而将深度推入3 mm需要平均86.8 N(n = 9)。结论:这些结果表明,较大直径的移植物的绝对值更稳定,而扩张长度越短,稳定性可能越高,而水平推入力却没有明显增加。连续或圆形植入的移植物之间的主要稳定性没有差异,在移植后的初期,多个移植物的稳定性可能不如单个移植物。临床相关性:这是一项随机,对照的体外动物试验,有助于我们更好地了解骨软骨移植物的主要稳定性,并完善手术技术和术后方案。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号