The effect of drill-hole length on the primary stability of osteochondral grafts in mosaicplasty.

机译:钻孔长度对镶嵌成形术中骨软骨移植物初始稳定性的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

Osteochondral grafts were transplanted from the trochlea of porcine femurs into drill holes that were 20, 15, and 12 mm in length on the lateral femoral condyle. Grafts initially were pushed in flush with the surrounding cartilage, and then a testing machine pushed the grafts 3 mm deeper. For the 20-, 15-, and 12-mm drill holes, mean forces for pushing the graft flush were 36.58, 43.33, and 118.13 N, respectively, while mean forces for pushing the graft 3 mm deeper were 122.50, 249.33, and 377.25 N, respectively. These results suggest primary stability is better when grafts and drill holes are the same length, but if the recipient hole is shorter, excessive force must be exerted on the cartilage cup during insertion.
机译:将骨软骨移植物从猪股骨的滑车移植到股骨外侧con长分别为20、15和12 mm的钻孔中。首先将移植物推入与周围软骨齐平的位置,然后用试验机将移植物推入深3毫米的位置。对于20毫米,15毫米和12毫米的钻孔,推动移植物平齐的平均力分别为36.58、43.33和118.13 N,而推动移植物深3毫米的平均力分别为122.50、249.33和377.25。 N分别。这些结果表明,当移植物和钻孔的长度相同时,初级稳定性会更好,但如果接收孔较短,则在插入过程中必须对软骨杯施加过大的力。