首页> 外文期刊>American Journal of Sports Medicine >Compaction drilling does not increase the initial fixation strength of the hamstring tendon graft in anterior cruciate ligament reconstruction in a cadaver model.
【24h】

Compaction drilling does not increase the initial fixation strength of the hamstring tendon graft in anterior cruciate ligament reconstruction in a cadaver model.

机译:压实钻孔不会在尸体模型中增加前交叉韧带重建中绳肌腱移植物的初始固定强度。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

BACKGROUND: Compaction of the bone tunnel walls has been proposed to increase the fixation strength of soft tissue grafts fixed with an interference screw in anterior cruciate ligament reconstructions. HYPOTHESIS: Compaction drilling does not increase the initial fixation strength of the hamstring tendon graft in comparison with conventional extraction drilling. STUDY DESIGN: Randomized experimental study. METHODS: Initial fixation strength of quadrupled hamstring tendon grafts fixed with bioabsorbable interference screws was assessed in 22 pairs of human cadaveric tibiae. Bone tunnels were drilled with either a compaction drill or a conventional extraction drill. Specimens underwent a cyclic-loading test and the surviving specimens were then loaded to failure in a single-cycle load-to-failure test. Trabecular bone mineral density at the site corresponding to the actual site of the tibial bone tunnel was determined by using peripheral quantitative computed tomography. RESULTS: During the cyclic-loadingtest, no significant stiffness or displacement differences were observed between the two drilling techniques. Three specimens failed in the compaction-drilling group, whereas there were no failures in the extraction-drilling group. In the subsequent single-cycle load-to-failure test, no significant differences between the two drilling techniques were found with regard to displacement at yield load, stiffness, or mode of failure. There was no significant difference in trabecular bone mineral density between the two groups. CONCLUSIONS: Compaction drilling does not increase the initial fixation strength of the hamstring tendon graft compared with conventional extraction drilling.
机译:背景:已经提出了对骨隧道壁的压实以增加在前交叉韧带重建中用干涉螺钉固定的软组织移植物的固定强度。假设:与常规拔牙钻孔相比,压实钻孔不会增加increase绳肌腱移植物的初始固定强度。研究设计:随机实验研究。方法:在22对人的尸体胫骨中评估了用生物可吸收的干扰螺钉固定的四足tend绳肌腱移植物的初始固定强度。用压紧钻或传统的抽气钻钻骨隧道。对样品进行循环加载测试,然后将幸存的样品通过单循环加载失败测试加载到失败。通过使用外周定量计算机断层扫描来确定与胫骨隧道实际位置相对应的位置的小梁骨矿物质密度。结果:在循环载荷试验中,两种钻井技术之间没有观察到明显的刚度或位移差异。压实钻孔组中有3个样品失败,而抽采钻孔组中没有任何失败。在随后的单周期载荷-破坏测试中,两种钻井技术在屈服载荷,刚度或破坏模式下的位移方面都没有发现显着差异。两组之间的小梁骨矿物质密度没有显着差异。结论:与常规拔牙钻孔相比,压实钻孔不会增加绳肌腱移植物的初始固定强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号