...
首页> 外文期刊>American Journal of Sports Medicine >Interference Screw Fixation of Soft Tissue Grafts in Anterior Cruciate Ligament Reconstruction: Part 1: Effect of Tunnel Compaction by Serial Dilators Versus Extraction Drilling on the Initial Fixation Strength.
【24h】

Interference Screw Fixation of Soft Tissue Grafts in Anterior Cruciate Ligament Reconstruction: Part 1: Effect of Tunnel Compaction by Serial Dilators Versus Extraction Drilling on the Initial Fixation Strength.

机译:前交叉韧带重建中软组织移植物的干涉螺钉固定:第1部分:串行扩张器对隧道压实与拔除钻孔对初始固定强度的影响。

获取原文
获取原文并翻译 | 示例

摘要

BACKGROUND: Compaction of the bone-tunnel walls by serial dilation is believed to enhance the interference screw fixation strength of the soft tissue grafts in anterior cruciate ligament (ACL) reconstruction. HYPOTHESIS: Serial dilation enhances the fixation strength of soft tissue grafts in ACL reconstruction over extraction drilling. STUDY DESIGN: Randomized experimental study. METHODS: Initial fixation strength of the doubled anterior tibialis tendon grafts (fixed with a bioabsorbable interference screw) was assessed in 21 pairs of human cadaver tibiae with either serially dilated or extraction-drilled bone tunnels. The specimens were subjected to a cyclic-loading test, and those surviving were then tested using the single-cycle load-to-failure test. RESULTS: During the cyclic-loading test, there were 3 fixation failures in the serially dilated and 6 failures in the extraction-drilled specimens but no significant stiffness or displacement differences between the groups. In the subsequent load-to-failure test, the average yield loads were 473 +/- 110 N and 480 +/- 115 N for the 2 groups respectively (P =.97) and no difference with regard to stiffness or mode of failure. CONCLUSIONS: Serial dilation does not increase the strength of interference fixation of soft tissue grafts in ACL reconstruction over extraction drilling. Clinical Relevance: The results of this experiment do not support the use of serial dilators in ACL reconstruction.
机译:背景:通过连续扩张来压实骨隧道壁可增强前交叉韧带(ACL)重建中软组织移植物的干涉螺钉固定强度。假设:连续扩张增强了软组织移植物在ACL重建中的固定强度,优于提取钻孔。研究设计:随机实验研究。方法:通过连续扩张或拔出钻孔的21对人尸胫骨,评估了双胫骨前肌腱移植物(用可生物吸收的干扰螺钉固定)的初始固定强度。对样品进行循环载荷测试,然后使用单循环载荷-破坏测试对存活的样品进行测试。结果:在循环载荷试验中,连续扩张中有3个固定失败,而提取钻孔标本中有6个失败,但两组之间没有明显的刚度或位移差异。在随后的载荷失效测试中,两组的平均屈服载荷分别为473 +/- 110 N和480 +/- 115 N(P = .97),并且在刚度或失效模式方面没有差异。结论:连续扩张不会增加ACL重建中软组织移植物在提取钻孔中的干扰固定强度。临床意义:该实验的结果不支持在ACL重建中使用串行扩张器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号