...
首页> 外文期刊>Acta physiologica Scandinavica >Non-invasive assessment of cardiac output during exercise in healthy young humans: comparison between Modelflow method and Doppler echocardiography method.
【24h】

Non-invasive assessment of cardiac output during exercise in healthy young humans: comparison between Modelflow method and Doppler echocardiography method.

机译:健康年轻人运动过程中心输出量的非侵入性评估:Modelflow方法与多普勒超声心动图方法之间的比较。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

AIMS: The Modelflow method can estimate cardiac output from arterial blood pressure waveforms using a three-element model of aortic input impedance (aortic characteristic impedance, arterial compliance, and systemic vascular resistance). We tested the reliability of a non-invasive cardiac output estimation during submaximal exercise using the Modelflow method from finger arterial pressure waveforms collected by Portapres in healthy young humans. METHODS: The Doppler echocardiography method was used as a reference method. Sixteen healthy young subjects (nine males and seven females) performed a multi-stage cycle ergometer exercise at an intensity corresponding to 70, 90, 110 and 130% of their individual ventilatory threshold for 2 min each. The simultaneous estimation of cardiac output (15 s averaged data) using the Modelflow and Doppler echocardiography methods was performed at rest and during exercise. RESULTS AND CONCLUSION: The Modelflow-estimated cardiac output correlated significantly with the simultaneous estimates by the Doppler method in all subjects (r = 0.87, P < 0.0001) and the SE of estimation was 1.93 L min-1. Correlation coefficients in each subject ranged from 0.91 to 0.98. Although the Modelflow method overestimated cardiac output, the errors between two estimates were not significantly different among the exercise levels. These results suggest that the Modelflow method using Portapres could provide a reliable estimation of the relative change in cardiac output non-invasively and continuously during submaximal exercise in healthy young humans, at least in terms of the relative changes in cardiac output.
机译:目的:Modelflow方法可以使用三要素主动脉输入阻抗(主动脉特征阻抗,动脉顺应性和全身血管阻力)模型从动脉血压波形估计心输出量。我们使用Modelflow方法从Portapres在健康年轻人中收集的手指动脉压力波形测试了次最大运动过程中无创心输出量估计的可靠性。方法:采用多普勒超声心动图法作为参考方法。十六名健康的年轻受试者(九名男性和七名女性)进行了多级循环测功计运动,其强度分别相当于其各自通气阈值的70%,90%,110%和130%,每次持续2分钟。在休息和运动过程中,使用Modelflow和多普勒超声心动图法同时估算心输出量(平均15 s数据)。结果与结论:在所有受试者中,Modelflow估算的心输出量与多普勒方法同时估算的相关性显着相关(r = 0.87,P <0.0001),估算的SE为1.93 L min-1。每个受试者的相关系数在0.91至0.98之间。尽管Modelflow方法高估了心输出量,但两次估计之间的误差在运动水平之间并无显着差异。这些结果表明,使用Portapres的Modelflow方法可以提供可靠的估计,即至少在心输出量的相对变化方面,对健康的年轻人进行次最大运动时,其无创且连续地测量心输出量的相对变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号