首页> 外文期刊>Annals of allergy, asthma, and immunology >Comparison of the Multi-Test II and Skintestor Omni allergy skin test devices.
【24h】

Comparison of the Multi-Test II and Skintestor Omni allergy skin test devices.

机译:Multi-Test II和Skintestor Omni过敏皮肤测试设备的比较。

获取原文
获取原文并翻译 | 示例
获取外文期刊封面目录资料

摘要

BACKGROUND: Different devices for percutaneous allergy skin testing have demonstrated statistically and clinically significant differences in performance characteristics. OBJECTIVE: To compare 2 Food and Drug Administration-approved multihead allergy skin testing devices: Multi-Test II (Lincoln Diagnostics) and Skintestor Omni (Greer Laboratories). METHODS: Skin tests with glycerinated histamine (6-mg/mL base) and glycerinated saline were applied to 31 adults using Multi-Test II on the volar surface of one forearm and Skintestor Omni on the opposite forearm. RESULTS: Data were accumulated from 155 histamine sites and 93 negative control sites for each device. Using cutoff wheal sizes of 5 vs 3 mm inclusive to define a positive result, Multi-Test II sensitivity remained at 100%, but specificity increased from 74% to 97%, whereas Skintestor Omni sensitivity decreased from 94% to 87%, and specificity increased from 58% to 88%. For Multi-Test II vs Skintestor Omni, histamine mean (SD) wheal sizes were 9.23(1.37) vs 7.74 (2.83) mm (P < .001), mean coefficients of variance were 14.8% vs 36.6%, and pooled estimates of variance were 0.642 vs 6.974. Multi-Test II produced similar histamine wheal sizes regardless of test head position used, whereas Skintestor Omni produced statistically significantly smaller wheals at certain test head positions. CONCLUSIONS: Multi-Test II had higher sensitivity and specificity than Skintestor Omni and produced reproducible wheal sizes from all test head positions. Because some Skintestor Omni test head positions produced significantly smaller histamine wheal sizes, skin testing using this device might result in underdiagnosis of allergy.
机译:背景:用于经皮过敏性皮肤测试的不同设备已证明其性能特征在统计学上和临床上都存在显着差异。目的:比较两种获得食品药品监督管理局批准的多头过敏皮肤测试设备:Multi-Test II(林肯诊断)和Skintestor Omni(Greer实验室)。方法:使用Multi-Test II在一只前臂的掌侧表面上使用甘油化的组胺(6-mg / mL碱)和甘油化的盐水对31位成年人进行皮肤测试,在另一只前臂的Skintestor Omni上进行皮肤测试。结果:从每个设备的155个组胺位点和93个阴性对照位点收集了数据。使用5毫米和3毫米(含3mm)的切块尺寸来定义阳性结果,Multi-Test II敏感性保持在100%,但特异性从74%提高到97%,而Skintestor Omni敏感性从94%降低到87%,特异性从58%增加到88%。对于Multi-Test II与Skintestor Omni,组胺平均(SD)的风团大小为9.23(1.37)对7.74(2.83)mm(P <.001),平均方差系数为14.8%对36.6%,汇总方差估计分别为0.642和6.974。无论使用哪种测试头位置,Multi-Test II都能产生相似的组胺团块尺寸,而Skintestor Omni在某些测试头位置处产生的统计学上明显较小的团块。结论:Multi-Test II比Skintestor Omni具有更高的灵敏度和特异性,并且在所有测试头位置均可产生可再现的鲸鱼大小。由于某些Skintestor Omni测试头位置产生的组胺皮明显较小,因此使用此设备进行皮肤测试可能会导致对过敏的诊断不足。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号