首页> 外文期刊>Biomedical Chromatography: An International Journal Devoted to Research in Chromatographic Methodologies and Their Applications in the Biosciences >A rapid and sensitive determination of hypoxic radiosensitizer agent nimorazole in rat plasma by LC-MS/MS and its application to a pharmacokinetic study
【24h】

A rapid and sensitive determination of hypoxic radiosensitizer agent nimorazole in rat plasma by LC-MS/MS and its application to a pharmacokinetic study

机译:LC-MS / MS快速灵敏地测定大鼠血浆中缺氧放射增敏剂尼莫拉唑及其在药代动力学研究中的应用

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

A highly sensitive, accurate and robust LC-MS/MS method was developed and validated for determination of nimorazole (NMZ) in rat plasma using metronidazole (MNZ) as internal standard (IS). The analyte and IS were extracted from plasma by precipitating protein with acetonitrile and were chromatographed using an Agilent Poroshell 120, EC-C-18 column. The mobile phase was composed of a mixture of acetonitrile and 0.1 % formic acid (85:15v/v). The total run time was 1.5min and injection volume was 5L. Multiple reaction monitoring mode using the transitions of m/z 227.1m/z 114.0 for MNZ and m/z 172.10m/z 128.1 for IS were monitored on a triple quadrupole mass spectrometer, operating in positive ion mode. The calibration curve was linear in the range of 0.25-200ng/mL (r(2)>0.9996) and the lower limit of quantification was 0.25ng/mL in the rat plasma samples. Recoveries of NMZ ranged between 88.05 and 95.25%. The precision (intra-day and inter-day) and accuracy of the quality control samples were 1.25-8.20% and -2.50-3.10, respectively. The analyte and IS were found to be stable during all sample storage and analysis procedures. The LC-MS/MS method described here was validated and successfully applied to pharmacokinetic study in rats. Copyright (c) 2015 John Wiley & Sons, Ltd.
机译:开发了一种高度灵敏,准确和耐用的LC-MS / MS方法,并已验证了使用甲硝唑(MNZ)作为内标(IS)测定大鼠血浆中的尼莫拉唑(NMZ)的能力。通过用乙腈沉淀蛋白质从血浆中提取分析物和IS,并使用Agilent Poroshell 120,EC-C-18色谱柱进行色谱分离。流动相由乙腈和0.1%甲酸(85:15v / v)的混合物组成。总运行时间为1.5分钟,进样量为5L。在正离子模式下的三重四极杆质谱仪上,使用MNZ的m / z 227.1m / z 114.0和IS的m / z 172.10m / z 128.1的跃迁进行多反应监测模式。在大鼠血浆样品中,校准曲线在0.25-200ng / mL范围内呈线性(r(2)> 0.9996),定量下限为0.25ng / mL。 NMZ的回收率介于88.05和95.25%之间。质量控制样品的精度(日内和日间)和准确度分别为1.25-8.20%和-2.50-3.10。发现在所有样品存储和分析过程中,分析物和IS均稳定。本文所述的LC-MS / MS方法经过验证,已成功应用于大鼠的药代动力学研究。版权所有(c)2015 John Wiley&Sons,Ltd.

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号