Using both experimental assays and fluid-dynamic finite element simulation models, we directly compared the achievable performance limits of four distinct assay configurations for label-free detection of an analyte from a test sample on a biosensor surface. The assay configurations studied in this work included a biosensor incorporated into the bottom surface of a microplate well and a microfluidic channel. For each configuration, we compared assay performance for the scenario in which the entire bottom surface of the fluid-handling vessel is coated with capture ligands with assay performance for the scenario in which the capture ligands are applied in the form of localized spots. As a model system, we used detection of the protein biomarker tumor necrosis factor-alpha (TNF-α) using immobilized TNF-α capture antibody. Results show that the microfluidic assay format dramatically reduces the time required to establish a stable equilibrium. Spot-based assays are advantageous for microplate-based detection for reducing the time required for equilibrium sensor response. The results derived are generally applicable to any label-free biosensor technology and any ligand-analyte system with adjustable variables that include sensor mass density sensitivity, analyte-ligand adsorption/desorption rate constants, immobilized ligand density, flow channel geometry, flow rate, and spot size.
机译:使用实验分析和流体动力学有限元模拟模型,我们直接比较了四种不同分析配置可实现的性能极限,这些配置用于无标记检测生物传感器表面上的测试样品中的分析物。在这项工作中研究的测定配置包括整合到微孔板底表面和微流体通道中的生物传感器。对于每种配置,我们比较了其中流体处理容器的整个底表面都覆盖有捕获配体的方案的检测性能和其中以局部斑点形式应用捕获配体的方案的检测性能。作为模型系统,我们使用固定的TNF-α捕获抗体检测蛋白质生物标志物肿瘤坏死因子-α(TNF-α)。结果表明,微流体分析形式显着减少了建立稳定平衡所需的时间。基于斑点的测定法有利于基于微孔板的检测,可减少平衡传感器响应所需的时间。得出的结果通常适用于任何无标记生物传感器技术和具有可调变量的任何配体-分析物系统,这些变量包括传感器质量密度灵敏度,分析物-配体吸附/解吸速率常数,固定的配体密度,流道几何形状,流速和斑点大小。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号