首页> 外文期刊>Analytical and bioanalytical chemistry >An improved and fast UHPLC-PDA methodology for determination of L-ascorbic and dehydroascorbic acids in fruits and vegetables. Evaluation of degradation rate during storage
【24h】

An improved and fast UHPLC-PDA methodology for determination of L-ascorbic and dehydroascorbic acids in fruits and vegetables. Evaluation of degradation rate during storage

机译:一种改进的快速UHPLC-PDA方法,用于测定水果和蔬菜中的L-抗坏血酸和脱氢抗坏血酸。储存期间的降解率评估

获取原文
获取原文并翻译 | 示例
           

摘要

This study provides a versatile validated method to determine the total vitamin C content, as the sum of the contents of L-ascorbic acid (L-AA) and dehydroascorbic acid (DHAA), in several fruits and vegetables and its degradability with storage time. Seven horticultural crops from two different origins were analyzed using an ultra-high-performance liquid chromatographic-photodiode array (UHPLC-PDA) system, equipped with a new trifunctional high strength silica (100% silica particle) analytical column (100 mm×2.1 mm, 1.7 μm particle size) using 0.1% (v/v) formic acid as mobile phase, in isocratic mode. This new stationary phase, specially designed for polar compounds, overcomes the problems normally encountered in HPLC and is suitable for the analysis of large batches of samples without L-AA degradation. In addition, it proves to be an excellent alternative to conventional C18 columns for the determination of L-AA in fruits and vegetables. The method was fully validated in terms of linearity, detection (LOD) and quantification (LOQ) limits, accuracy, and inter/intraday precision. Validation experiments revealed very good recovery rate of 96.6±4.4% for L-AA and 103.1±4.8 % for total vitamin C, good linearity with r ~2-values <0.999 within the established concentration range, excellent repeatability (0.5%), and reproducibility (1.6%) values. The LOD of the method was 22 ng/mL whereas the LOQ was 67 ng/mL. It was possible to demonstrate that L-AA and DHAA concentrations in the different horticulture products varied oppositely with time of storage not always affecting the total amount of vitamin C during shelf-life. Locally produced fruits have higher concentrations of vitamin C, compared with imported ones, but vegetables showed the opposite trend. Moreover, this UHPLC-PDA methodology proves to be an improved, simple, and fast approach for determining the total content of vitamin C in various food commodities, with high sensitivity, selectivity, and resolving power within 3 min of run analysis.
机译:这项研究为确定几种水果和蔬菜中L-抗坏血酸(L-AA)和脱氢抗坏血酸(DHAA)的含量之和以及其随储存时间的可降解性提供了一种通用的经验证的方法来测定总维生素C含量。使用配备了新型三功能高强度二氧化硅(100%二氧化硅颗粒)分析柱(100 mm×2.1 mm)的超高效液相色谱-光电二极管阵列(UHPLC-PDA)系统分析了来自两个不同来源的七种园艺作物(1.7μm粒径),使用0.1%(v / v)甲酸作为流动相,等度模式。这种新的固定相专为极性化合物而设计,克服了HPLC中通常遇到的问题,适用于分析大批样品而没有L-AA降解。此外,它被证明是测定水果和蔬菜中L-AA的传统C18色谱柱的极佳替代品。该方法在线性,检测(LOD)和定量(LOQ)限度,准确性和日间/日间精度方面得到了充分验证。验证实验显示,L-AA的回收率非常好,总维生素C的回收率为96.6±4.4%,线性良好,在确定的浓度范围内r〜2-值<0.999,线性良好,重复性极佳(0.5%),并且重现性(1.6%)值。该方法的LOD为22 ng / mL,而LOQ为67 ng / mL。有可能证明,不同园艺产品中的L-AA和DHAA浓度随储存时间的变化而相反,并不总是影响货架期内维生素C的总量。与进口水果相比,本地生产的水果中维生素C的浓度更高,但蔬菜却呈现相反的趋势。而且,该UHPLC-PDA方法被证明是一种测定各种食品中维生素C总含量的改进,简单且快速的方法,在运行分析后3分钟之内具有高灵敏度,选择性和分辨能力。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号