Methyl tert-butyl ether (MTBE) is a common groundwater contaminant, introduced to the environment by leaking petroleum storage tanks, urban runoff, and motorized watercraft. In this study. a simplified (static) headspace analysis method was adapted for determination of MTBE in water samples and soil water extracts. The MDL of the headspace method was calculated to be 2.0 mug L-1 by the EPA single-concentration design method(1) and 1.2 mug L-1 by a calibration method developed by Hubaux and Vos (Hubaux, A.; Vos, G. Anal. Chem. 1970,42, 849-855). The MDL calculated with the Hubaux and Vos method was favored because it considers both a true positive and a false positive. The static headspace method was applied to analysis of a tap water sample and a monitoring well sample from a gasoline service station, a river sample, and aqueous extracts from soil excavated during removal of a leaking underground storage tank (LUST). The water samples examined in this study had MTBE concentrations ranging from 6 to 19 mug L-1. Aqueous extracts of a soil sample taken from the LUST site had 8 mug L-1 MTBE. [References: 19]
机译:甲基叔丁基醚(MTBE)是一种常见的地下水污染物,由于石油储存罐,城市径流和机动船只的泄漏而引入环境。在这个研究中。一种简化的(静态)顶空分析方法适用于测定水样和土壤水提取物中的MTBE。顶空法的MDL通过EPA单浓度设计方法(1)计算为2.0马克杯L-1,通过Hubaux和Vos(Hubaux,A .; Vos,G (Anal.Chem.1970,42,849-855)。使用Hubaux和Vos方法计算的MDL是受青睐的,因为它同时考虑了真阳性和假阳性。静态顶空法用于分析汽油加油站的自来水样品和监测井样品,河流样品以及在拆除泄漏的地下储罐(LUST)期间挖掘的土壤中的水提取物。在这项研究中检查的水样本的MTBE浓度范围为6到19马克杯L-1。从LUST站点获取的土壤样品的水提物具有8杯L-1 MTBE。 [参考:19]

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号