首页> 外文期刊>Analytical and bioanalytical chemistry >Quantification of dehydroepiandrosterone in human serum on a routine basis: development and validation of a tandem mass spectrometry method based on a surrogate analyte
【24h】

Quantification of dehydroepiandrosterone in human serum on a routine basis: development and validation of a tandem mass spectrometry method based on a surrogate analyte

机译:常规基于替代分析物的人血清中脱氢贫康松的定量:基于替代分析物的串联质谱法的开发与验证

获取原文
获取原文并翻译 | 示例

摘要

AbstractIn the clinical laboratories, dehydroepiandrostenedione (DHEA) is usually quantified by immunoassay-based methods, which are often affected by cross-reactivity with endogenous interferences, such as 4-androsten-3β-ol-17-one. The interfering compounds lead to a poor accuracy of the measurements, mainly at a low concentration level. The present paper describes a validated method based on tandem mass spectrometry coupled to liquid chromatography, for the accurate quantification of DHEA in serum. The peculiarity of this method is the use of calibrators and quality controls prepared by adding measured amounts of DHEA-D5, a stable isotope-labeled analogue of DHEA, to real serum from healthy subjects. DHEA-D5is used in place of DHEA, which is usually present in unstripped serum at physiological levels, as it has the same basic structure, provides an equivalent instrumental response, and can be easily distinguish by DHEA by mass spectrometry due to its differentm/zvalue. The method proved to be sensitive, with a LLOD of 0.09?ng/mL and a LLOQ of 0.23?ng/mL, and selective, with overall performances that allow its use on a routine basis.]]>
机译:<![cdata [ <标题>抽象 ara id =“par1”>在临床实验室中,脱氢铁卓索丁(DHEA)通常是通过基于免疫测定的方法量化,其通常受与内源干扰的交叉反应性的影响,例如4-androsten-3β-OL-17-one。干扰化合物导致测量的较差差,主要是低浓度水平。本文介绍了一种基于串联质谱法耦合到液相色谱的验证方法,用于准确定量血清DHEA。该方法的特殊性是通过将测量量的DHEA-D <下标> 5 ,将DHEA的稳定同位素标记的类似物的测量量的DHEA-D <下标>,从健康受试者中稳定地使用校准剂和质量控制。使用DHEA-D <下标> 5 代替DHEA,其通常存在于生理水平上的未充分的血清中,因为它具有相同的基本结构,提供了等效的仪器反应,并且可以轻松区分DHEA由于其不同的<重点类型=“斜体”> m / <重点=“斜体”> z 值,因此通过质谱谱图。该方法被证明是敏感的,LLOD为0.09?Ng / ml,LLOQ为0.23Ω·Ng / ml,以及选择性,整体性能允许其在常规的基础上使用。 ] ]

著录项

  • 来源
  • 作者单位

    Department of Translational Research and of New Surgical and Medical Technologies University of Pisa;

    Department of Surgical Medical and Molecular Pathology and Critical Care Medicine University of Pisa;

    Department of Medical Oncology Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori (IRST) IRCCS;

    Unit of Biostatistics and Clinical Trials Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori (IRST) IRCCS;

    Oncology Pharmacy Laboratory Istituto Scientifico Romagnolo per lo Studio e la Cura dei Tumori (IRST) IRCCS;

    Perkin Elmer Italia S.p.A;

    Pediatric Division Department of Obstetrics Gynecology and Pediatrics St. Chiara University Hospital;

    Department of Translational Research and of New Surgical and Medical Technologies University of Pisa;

    Department of Surgical Medical and Molecular Pathology and Critical Care Medicine University of Pisa;

    Department of Surgical Medical and Molecular Pathology and Critical Care Medicine University of Pisa;

  • 收录信息
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 分析化学;
  • 关键词

    DHEA; DHEA-D5; Laboratory medicine; Liquid chromatography; Tandem mass spectrometry;

    机译:DHEA;DHEA-D5;实验室药;液相色谱;串联质谱;

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号