首页> 外文期刊>CERAMICS INTERNATIONAL >Ablation resistance of TaC-modified HfC coating prepared by supersonic plasma spraying for SiC-coated carbon/carbon composites
【24h】

Ablation resistance of TaC-modified HfC coating prepared by supersonic plasma spraying for SiC-coated carbon/carbon composites

机译:通过用于SiC涂层碳/碳复合材料的超声等离子体喷涂制备TAC改性HFC涂层的消融抗性

获取原文
获取原文并翻译 | 示例
           

摘要

A HfC-TaC composite coating was prepared on SiC-coated C/C composites by supersonic atmosphere plasma spraying (SAPS) to improve their ablation resistance. The ablation resistance was evaluated under oxyacetylene torch with heat flux of 2.38 MW/m(2) and 4.18 MW/m(2) respectively, and the effect of TaC on microstructure and phase composition of the coating was investigated. Results showed that TaC-modified HfC coating exhibited good ablation resistance under the torch with heat flux of 2.38 MW/m(2) and its mass and linear ablation rates were -0.35 mg/s and -1.05 mu m/s separately, which is ascribed to the formation of continuous oxide film including phases like Hf6Ta2O37 and Ta2O5. Crack propagation in the coating was inhibited due to the phase transition restriction of HfO2 by Ta2O5, and cracks and holes in the oxide layer could be repaired by molten Ta2O5 and Hf6Ta2O17. However, the occurrence of ablation crater on the surface of HfC-TaC coating is mainly attributed to the unsatisfactory scouring resistance of the oxide film under heat flux of 4.18 MW/m(2).
机译:通过超声气氛等离子体喷涂(SAP)在SiC涂覆的C / C复合材料上制备HFC-TAC复合涂层,以改善它们的消融抗性。在氧基乙炔炬下,分别在氧乙炔炬下评价消融抗性,分别为2.38mW / m(2)和4.18mW / m(2),并研究了TAC对涂层的微观结构和相组成的影响。结果表明,TAC改性的HFC涂层在带有2.38mW / m(2)的热通量下的焊炬下的良好消融电阻,其质量和线性消融率分别为-0.35mg / s和-1.05μm/ s,即归因于形成连续氧化物膜,包括类似HF6TA2O37和TA2O5的相。由于HFO2的相转变限制通过Ta 2 O 5的相变限制,抑制涂层中的裂纹传播,并且氧化物层中的裂缝和孔可以通过熔融Ta2O5和HF6TA2O17修复。然而,HFC-TAC涂层表面上的消融陨石坑的发生主要归因于氧化膜在4.18mW / m(2)的热通量下的不令人满意的污水抗性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号