首页> 外文期刊>Behavioural Brain Research: An International Journal >Applicability of the grip strength and automated von Frey tactile sensitivity tests in the mouse photothrombotic model of stroke
【24h】

Applicability of the grip strength and automated von Frey tactile sensitivity tests in the mouse photothrombotic model of stroke

机译:握力和自动von毛细血管触觉敏感性脑卒中小鼠鼠窜强度触觉敏感性试验的适用性

获取原文
获取原文并翻译 | 示例
           

摘要

Improvement of impaired neurological function(s) is a primary endpoint in experimental stroke recovery studies, making the choice and nature of the functional tests crucial for proper execution and interpretation of such studies. Currently, there are a limited number of neurological tests which reliably evaluate functional deficit in mice over a long period of time after stroke. In this study, we evaluated the applicability of forepaw grip strength and automated von Frey tactile sensitivity tests to assess forelimb dysfunction in mice following photo thrombosis in the sensorimotor cortex, and compared them with two well-established tests, grid-walking and cylinder, for up to 21 days after stroke. Our results indicate that the length of time required to conduct the two new tests is comparable to that of the grid-walking and cylinder tests, however the data from the new tests is obtained and ready for analysis upon completion of the testing session. In addition, our observations indicate that the automated von Frey test detected substantial and sustained deficit in the withdrawal threshold of the mice on all evaluation days after stroke, whereas the forepaw grip strength test was only marginally sensitive to document functional impairment. Our data demonstrate that the automated von Frey tactile sensitivity test is a time efficient and sensitive method which can be used together with other established tests to evaluate long-term functional outcome in the mouse photothrombotic stroke model.
机译:神经功能障碍的改善是实验性卒中恢复研究中的主要终点,使功能性测试的选择和性质至关重要,以便适当执行和对这些研究的解释。目前,存在有限数量的神经系统试验,其在中风后长时间在小鼠中可靠地评估小鼠的功能缺陷。在这项研究中,我们评估了前爪握持强度和自动von Frey触觉敏感性试验的适用性,以评估SensorImotor皮层的照片血栓形成后小鼠的前列功能障碍,并将它们与两个良好的测试,走路和气缸进行比较。中风最长21天。我们的结果表明,进行两次新测试所需的时间长度与网格行走和汽缸测试的时间长度相当,但是在完成测试会话时获得了来自新测试的数据并准备进行分析。此外,我们的观察表明,自动von Frey检验在中风后所有评估日对小鼠的戒断阈值中检测到大量和持续的缺陷,而前爪握力试验仅对文档功能损伤略微敏感。我们的数据表明,自动von Frey触觉敏感性测试是一种时间效率和敏感方法,可以与其他建立的测试一起使用,以评估小鼠photcotholy中风模型中的长期功能结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号