Electrical head-only stunning is a widely used method in sheep (Ovis aries) slaughter. To investigate the influence of current level on stun and meat quality in practice, two studies were carried out at a commercial slaughterhouse. In trial one, 200 lambs were randomly assigned to four groups with a current level of 0.6, 0.8, 1.0 and 1.25 A, respectively, using 50-Hz sine wave supply voltage and a stun duration of 10.5 s. In trial two, 135 lambs were randomly assigned to two groups, with electrical current of 1.25 A applied for 14 and 3 s. For each lamb, the position of the tongs was observed and classified as correct or incorrect. The stun quality was evaluated based on observations of the corneal reflex, eye movements, rhythmic breathing, head-righting reflex and kicking during the tonic phase. Blood splash (haemorrhages in Longissimus dorsi muscle) was evaluated four days after slaughter. Incorrect tongs' positioning was seen commonly, and positively correlated with poor stun quality. The lowest current level tested produced an unsatisfactory stun in the majority of animals observed. Short stun duration increased the risk of a poor stun quality. There was no significant effect of current level, stun duration or tongs' position on the risk of blood splash. These data underline the importance of a correct technique, including choice of tongs' positioning, sufficient current levels and sufficient stun duration, for electrical stunning of lambs to achieve unconsciousness before sticking and thereby avoiding unnecessary suffering at commercial slaughter.
机译:仅电击晕是在绵羊(Ovis aries)屠宰中广泛使用的方法。为了在实践中调查当前水平对眩晕和肉质的影响,在一家商业屠宰场进行了两项研究。在试验一中,使用50 Hz正弦波供电电压和10.5 s的电晕持续时间,将200只羔羊随机分配到四组,电流水平分别为0.6、0.8、1.0和1.25A。在第二项试验中,将135只羔羊随机分为两组,分别在1.25 A和14 s的电流下施加3 s。对于每只羔羊,观察钳子的位置并将其分类为正确或不正确。根据在补药阶段观察到的角膜反射,眼球运动,节律性呼吸,头部扶正反射和脚踢来评估眩晕的质量。屠宰四天后评估血溅(背最长肌的出血)。钳子定位不正确的现象普遍存在,并且与昏迷质量呈正相关。测试的最低电流水平在大多数观察到的动物中产生了不令人满意的眩晕。昏迷持续时间短会增加昏迷质量的风险。当前的水平,昏迷的持续时间或钳子的位置对血溅的风险没有显着影响。这些数据强调了正确技术的重要性,包括选择钳子的位置,足够的电流水平和足够的击晕持续时间,以使羔羊电击昏以在粘连之前失去知觉,从而避免在商业屠宰中遭受不必要的痛苦。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号