Evaluation of a clinic-based cholinesterase test kit for the Washington State Cholinesterase Monitoring Program.

机译:针对华盛顿州胆碱酯酶监测计划的基于临床的胆碱酯酶测试试剂盒的评估。

获取原文
获取原文并翻译 | 示例

摘要

BACKGROUND: The Washington State Cholinesterase Monitoring Program for pesticide handlers requires blood draws at local clinics, with samples tested at a central laboratory. At present, workers with inhibited cholinesterase activity may be re-exposed before they can be removed from work. In this study we explored the option of on-site testing at local clinics using the EQM Test-mate Kittrade mark, a portable cholinesterase test kit. METHODS: Test kit cholinesterase activity measurements were performed on 50 blood samples by our research staff, and compared to measurements on the same samples by the Washington State Public Health Laboratory. Another set of samples was also analyzed with the test kit by medical staff at an eastern Washington clinic. RESULTS: Triplicate measurements with the test kit had a 3.3% average coefficient of variation (CV) for plasma cholinesterase (PChE), and a 3.5% average CV for erythrocyte cholinesterase (AChE) measurements. The kit's PChE measurements were similar to PHL measurements (average ratio of 0.98) when performed in the laboratory, but had a tendency to underestimate activity when used in the clinic setting (average ratio of 0.87). The kit systematically overestimated AChE activity by 42-48% relative to the PHL measurements, regardless of where the samples were analyzed. CONCLUSIONS: This easy-to-use test kit appeared to be a viable method for clinic-based PChE measurements, but was less consistent for AChE measurements performed in the clinic. Absolute measurements with the kit need to be evaluated carefully relative to standardized methods.
机译:背景:针对农药从业者的华盛顿州胆碱酯酶监测计划要求在当地诊所抽血,并在中央实验室测试样品。目前,胆碱酯酶活性受到抑制的工人可能需要重新暴露后才能下班。在这项研究中,我们探索了使用便携式胆碱酯酶测试试剂盒EQM Test-mate Kittrade标志在当地诊所进行现场测试的选择。方法:我们的研究人员对50个血液样本进行了测试试剂盒胆碱酯酶活性的测量,并与华盛顿州公共卫生实验室对相同样本的测量结果进行了比较。华盛顿东部一家诊所的医务人员还使用测试套件对另一组样品进行了分析。结果:使用该试剂盒进行的一式三份测量,血浆胆碱酯酶(PChE)的平均变异系数(CV)为3.3%,红细胞胆碱酯酶(AChE)的平均变异系数为3.5%。该试剂盒的PChE测量值在实验室中与PHL测量值相似(平均比率为0.98),但在临床环境中使用时有可能低估活性(平均比率为0.87)。无论在何处分析样品,该试剂盒都会相对于PHL测量系统高估AChE活性42-48%。结论:这种易于使用的测试套件似乎是用于基于临床的PChE测量的可行方法,但与在诊所进行的AChE测量的一致性较差。套件的绝对测量需要相对于标准化方法进行仔细评估。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号