A novel, accurate, simple and selective LC-MS/MS method was developed and validated for the determination of metoprolol in human plasma. Due to structural resemblance Propranolol was selected as internal standard. Anti coagulant used was K2 EDTA. Metoprolol, used in the therapy and management of hypertension, myocardial infraction and other cardio vascular diseases. Liquid - liquid extraction technique with tert-butyl methyl ether was applied for the extraction of analyte from human plasma. Kromasil C18 column (5 mu, 100 x 4.6 mm) with an isocratic mobile phase of 5mM Ammonium Formate pH 3.5 and Acetonitrile (15:85 V/V) was used for the resolution. Sample ionization was done with Electrospray ionization technique in positive ion mode. Selectivity was enhanced by tandem mass spectrometric analysis via two multiple reaction monitoring (MRM) transitions, m/z 268.15 -> 415.90 for metoprolol and 260.17 -> 415.90 for Propranolol respectively. The linearity of the method was established over a concentration range of 1.505 - 538.254 ng/mL, in human plasma, with the precision and accuracy ranging from 4.67 to 7.41% and 90.66 to 98.15% respectively. The stability of the analyte was evaluated in plasma under different storage conditions.
机译:开发并验证了一种新颖,准确,简单和选择性的LC-MS / MS方法,用于测定人血浆中的氟洛尔罗基。由于结构相似性丙醇醇被选为内标。使用的抗凝血剂是K2 EDTA。美托洛尔,用于治疗和管理高血压,心肌梗死和其他心血管疾病。用叔丁基甲基醚液 - 液提取技术施用来自人血浆的分析物的萃取。 kromasil C18柱(5μm,100×4.6mm),具有5mm氨基铵pH 3.5和乙腈(15:85V / v)的分辨率。用阳性离子模式用电喷雾电离技术进行样品电离。通过两种多重反应监测(MRM)转变,M / Z 268.15-> 415.90用于氟洛尔醇的两种多重反应监测(MRM)和260.17-> 415.90分别通过用于普萘洛尔的选择性来增强选择性。该方法的线性度在人血浆中的1.505-538.254 ng / ml的浓度范围内建立,精度和精度范围为4.67%至7.41%和90.66至98.15%。在不同的储存条件下在血浆中评价分析物的稳定性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号