摘要

PURPOSE: Previous studies have hypothesized unequal load sharing between peripheral and core sutures in flexor tendon repairs. Most commonly peripheral sutures are placed very near the repair site and characteristically fail before the core strands. We hypothesized that placement of the peripheral sutures farther from the repair site would better optimize load sharing and resist suture pullout, yielding a stronger overall repair. METHODS: To test the hypothesis we developed a mathematical model of the load sharing between core and peripheral sutures. By using this model we predicted that placement of peripheral sutures 2 mm from the repair site would optimize the balance of load between core and peripheral sutures. We then divided and repaired 27 flexor digitorum profundus tendons in 6 ways (core plus peripheral or peripheral sutures only at 1 mm, 2 mm, or 3 mm from the repair site). Tendons were clamped to a custom-built linear loading machine and distracted to failure. RESULTS: There was a clinicallyand statistically significant increase in strength with an increased distance of the peripheral suture from the repair site showing that core sutures augmented by a 2-mm peripheral repair were stronger than those performed with 1-mm peripheral repairs (50.8 vs 37.1 N). CONCLUSIONS: A peripheral stitch placement approximately 2 mm from the repair site represents a simple modification that can significantly increase the ultimate strength of flexor tendon repairs.
机译:目的:以前的研究在屈肌肌腱修理中的周边和核心缝合线之间假设不等载荷。最常见的周边缝合线放置在修复站点附近,并且在核心股之前的特征失败。我们假设远离修复现场的外围缝合线的放置更好地优化负载分配和抵抗缝合拔出,产生更强的整体修复。方法:测试假设,我们开发了核心和外围缝合线之间负载共享的数学模型。通过使用该模型,我们预测,从修复站点的外围缝合线的位置将优化核心和外围缝合线之间的负载的平衡。然后,我们以6种方式(核心加上外周或外周缝合线仅在1毫米,2毫米或3毫米)中划分和修复了27个屈肌Difitorum Profuncucus肌腱。肌腱被夹紧在定制的线性装载机上并分散注意力。结果:临床上有统计学上显着的强度升高,随着修复位点,外周缝合线的距离增加,显示由2mm周围修复增强的核心缝线比1mm周边修理(50.8 Vs 37.1)更强。 n)。结论:距离修复场地约2毫米的外围针脚放置代表了一个简单的改进,可以显着提高屈肌肌腱修理的极限强度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号