首页> 外文期刊>Journal of clinical laboratory analysis. >Performance comparison of blood collection tubes as liquid biopsy storage system for minimizing cfDNA contamination from genomic DNA
【24h】

Performance comparison of blood collection tubes as liquid biopsy storage system for minimizing cfDNA contamination from genomic DNA

机译:血液收集管作为液体活检储存系统的性能比较最小化基因组DNA的CFDNA污染

获取原文
获取原文并翻译 | 示例
           

摘要

Background The ratio of target cfDNA in total plasma is low. The abundant gDNA background resulting from blood cell lysis caused by improper operation has become a major obstacle to accurately measure cfDNA. In this study, we investigated the storage capacity of three blood cell collection tubes (BCTs) in the prevention of genomic DNA contamination caused by white blood cell rupture and evaluated their performance when they were utilized combining with highly sensitive mutation detection technology. Methods Blood samples were drawn from six healthy blood donors and stored in three types of BCTs (BD K-2-EDTA tube, Roche tube, and Streck tube). Plasma samples were isolated at specific time points (day 0, day 3, day 7, and day 14) for content analysis. Results Roche BCT was more capable for preventing cfDNA contamination caused by white blood cell disruption within 14 days, comparing with BD K-2-EDTA tube and Streck tube. Severe white blood cell lysis and gDNA contamination were found in the BD tube. The impacts of Roche and Streck tubes on the quantity and complexity of next-generation sequencing (NGS) libraries did not differ significantly within 3 days, satisfying most of our daily demands. In addition, the rupture of WBC was not synchronized with hemolysis in BCTs. Conclusion This study showed that capacities of blood collection tubes differed considerably in preservation of blood samples. Therefore, suitable blood collection devices should be selected to minimize gDNA contamination and to standardize blood samples processing for achieving more accurate and reliable clinical analysis of cfDNA.
机译:背景技术总血浆中的靶CFDNA的比率低。由于操作不当引起的血细胞裂解导致的丰富的GDNA背景已成为准确测量CFDNA的主要障碍。在这项研究中,我们研究了三种血细胞收集管(BCT)的储存能力在预防白细胞破裂引起的基因组DNA污染中,并在利用高度敏感的突变检测技术结合时评估它们的性能。方法从六种健康的血液供体中抽取血液样品并储存在三种类型的BCT(BD K-2-EDTA管,罗氏管和斑点管)中。在特定时间点(第0天,第3天,第7天和第14天)分离血浆样品用于内容分析。结果Roche BCT更有能力能够在14天内预防白细胞破坏引起的CFDNA污染,与BD K-2-EDTA管和STRECK管相比。在BD管中发现严重的白细胞裂解和GDNA污染。 Roche和STRECK管对下一代测序(NGS)文库的数量和复杂性的影响在3天内没有显着差异,满足我们的大部分日常需求。此外,WBC的破裂与BCT中的溶血不同步。结论本研究表明,在保存血液样品中,血液收集管的能力大大不同。因此,应选择合适的血液收集装置以使GDNA污染最小化,并标准化血液样本处理,以实现更准确和可靠的CFDNA临床分析。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号