Diagonal haptic capture of a plate intraocular lens with 4 haptics

机译:具有4个触觉的板式眼内镜片对角线触觉捕获

获取原文
获取原文并翻译 | 示例
           

摘要

A technique of diagonal haptic capture of a plate intraocular lens (IOL) with 4 haptics for cases with insufficient posterior capsular support is presented. The diagonal haptics were captured through the capsulorhexis by sequentially depressing each side of the haptic beneath the rim of the capsulorhexis with a gentle pressure. The IOL is fixated by pure IOL-capsule capture without sulcus fixation of haptics. The technique was used in 12 eyes (12 patients). The IOLs were well centered within the follow-up period. No IOL malposition, pseudophacodonesis, pupil capture, pigmental dispersion, or high intraocular tension was observed postoperatively. Ultrasound biomicroscopy revealed that there was no chafing of the IOL with the posterior iris. The technique provided an instant and definitive fixation with high adaptability to different sizes of capsulorhexis, and thereby could reduce the risk for complications related to haptic-sulcus fixation. Copyright (C) 2020 Published by Wolters Kluwer on behalf of ASCRS and ESCRS
机译:提出了一种具有4个触觉的板眼内透镜(IOL)对斜面囊肿不足的情况下的斜面触觉捕获技术。通过柔和的压力顺序地按下毛囊下方的触觉缘下的每一侧沿着触觉的每一侧捕获对角线触觉。 IOL通过纯IOL胶囊捕获固定而没有静脉固定的触觉。该技术用于12只眼(12名患者)。 IOL在随访期内很好地集中在一起。术后不观察到IOL Morposition,Pseudophacodonesis,瞳孔捕获,色素分散或高眼内张力。超声波生物显微镜显示,IOL没有虹膜的溶解。该技术提供了瞬间和最终的固定,对不同尺寸的胶囊疏松症的适应性高,从而可以降低与触觉 - 硫磺固定相关的并发症的风险。版权所有(c)2020由Wolters Kluwer发布代表Ascrs和ESCRS

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号