首页> 外文期刊>Journal of cataract and refractive surgery >Repositioning a posteriorly dislocated silicone plate-haptic toric intraocular lens
【24h】

Repositioning a posteriorly dislocated silicone plate-haptic toric intraocular lens

机译:重新定位后脱位的硅胶板 - 触觉角状眼内透镜

获取原文
获取原文并翻译 | 示例

摘要

We describe a technique for repositioning an encapsulated, posteriorly dislocated silicone plate-haptic toric intraocular lens (IOL) while preventing further dislocation into the vitreous cavity. Sutures of 10-0 polypropylene were used to ensure safe retrieval of the dislocated IOL. An anterior vitrectomy was then performed to remove the contracted capsular bag around the IOL. The IOL fixation hole was temporarily externalized to allow quick and secure IOL fixation, eliminating the risk for losing the slippery silicone IOL into the vitreous cavity. Using this technique, the IOL was successfully placed in the proper position and resulted in good vision for the patient while avoiding the trauma of lens. exchange. (C) 2018 ASCRS and ESCRS
机译:我们描述了一种用于重新定位封装的后脱位的硅树脂板 - 触觉转矩眼透镜(IOL)的技术,同时防止进一步位错入玻璃体腔中。 10-0聚丙烯的缝合线用于确保脱位的IOL的安全检索。 然后进行前玻璃体切除术以在IOL周围除去挛缩的囊袋。 IOL固定孔被暂时外化,以便快速和安全的IOL固定,从而消除将滑硅IOL失去玻璃体腔的风险。 使用该技术,IOL成功地放置在适当的位置,并为患者导致良好的视觉,同时避免透镜创伤。 交换。 (c)2018年ASCRS和ESCRS