We present a method for calculating the ideal toric lens to implant in astigmatic patients following cataract surgery. We show that the online calculators provided by major toric IOL manufacturers are insufficient for both theoretical and practical reasons. We reveal important theoretical shortcomings in their approach, illustrated by a number of cases which demonstrate how the approach can lead to errors in lens selection. Our approach combines the spherical and cylindrical power calculations into one, and allows for lens data from any manufacturer to be used, eliminating the reliance on multiple programs.
机译:我们提出一种用于计算理想的复曲面晶状体以植入白内障手术后的散光患者中的方法。我们显示,主要的复曲面IOL制造商提供的在线计算器在理论和实践上均不够。我们通过一些案例说明了它们在方法上的重要理论缺陷,这些案例说明了该方法如何导致镜头选择错误。我们的方法将球面和圆柱光焦度计算合二为一,并允许使用任何制造商提供的镜片数据,从而消除了对多个程序的依赖。