...
首页> 外文期刊>Journal of Biomechanics >Effects of follower load and rib cage on intervertebral disc pressure and sagittal plane curvature in static tests of cadaveric thoracic spines
【24h】

Effects of follower load and rib cage on intervertebral disc pressure and sagittal plane curvature in static tests of cadaveric thoracic spines

机译:从动荷载与肋条静态椎间盘压力与矢状椎间盘弯曲的影响

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

The clinical relevance of mechanical testing studies of cadaveric human thoracic spines could be enhanced by using follower preload techniques, by including the intact rib cage, and by measuring thoracic intervertebral disc pressures, but studies to date have not incorporated all of these components simultaneously. Thus, this study aimed to implement a follower preload in the thoracic spine with intact rib cage, and examine the effects of follower load, rib cage stiffening and rib cage removal on inter vertebral disc pressures and sagittal plane curvatures in unconstrained static conditions. Intervertebral disc pressures increased linearly with follower load magnitude. The effect of the rib cage on disc pressures in static conditions remains unclear because testing order likely confounded the results. Disc pressures compared well with previous reports in vitro, and comparison with in vivo values suggests the use of a follower load of about 400 N to approximate loading in upright standing. Follower load had no effect on sagittal plane spine curvature overall, suggesting successful application of the technique, although increased flexion in the upper spine and reduced flexion in the lower spine suggest that the follower load path was not optimized. Rib cage stiffening and removal both increased overall spine flexion slightly, although with differing effects at specific spinal locations. Overall, the approaches demonstrated here will support the use of follower preloads, intact rib cage, and disc pressure measurements to enhance the clinical relevance of future studies of the thoracic spine. (C) 2016 Elsevier Ltd. All rights reserved.
机译:通过使用完整的肋骨,通过包括完整的肋骨,通过测量胸椎间盘压力,可以提高尸体人胸脊柱机械测试研究的临床相关性,但通过测量胸椎间盘压力,但迄今为止的研究尚未同时掺入所有这些组分。因此,本研究旨在在具有完整肋骨脊柱的胸椎脊柱中实施从属脊髓,并检查从动载荷,肋骨加强和肋腔在无约束静态条件下的椎体椎间盘压力和矢状平面曲线的影响。椎间盘压力随从动载荷幅度线性增加。肋骨对静态条件中磁盘压力的影响仍不清楚,因为测试订单可能会混淆结果。磁盘压力良好地与先前的报道在体外相比,与体内值的比较表明,使用约400 n的从动载荷载荷以在直立的状态下近似负载。从动载荷载荷对矢状平面脊柱曲率没有影响,表明该技术的成功应用,尽管上脊柱的屈曲和下脊椎的屈曲减小表明,从动荷载路径未得到优化。肋骨加强和去除均略微增加了整体脊柱屈曲,尽管在特定脊柱位置具有不同的效果。总体而言,这里证明的方法将支持使用从动件预载荷,完整的肋骨和盘压测量,以提高胸椎未来研究的临床相关性。 (c)2016 Elsevier Ltd.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号