Validity and reliability of the Modified Sphygmomanometer Test with fixed stabilization for clinical measurement of muscle strength

机译:固定稳定化改良血压计试验的有效性和可靠性,用于肌肉力量的临床测量

获取原文
获取原文并翻译 | 示例
       

摘要

Objective: To investigate the concurrent validity of the Modified Sphygmomanometer Test (MST) with fixed stabilization, compared to the portable dynamometer, and to verify its test-retest and inter-raterreliability. Methods: Methodological study. The muscle strength of the following groups was measured: flexors and extensors of the wrist, of the hip, and of the knee and plantar flexors. The Tycos aneroid sphygmomanometer and the Microfet 2 dynamometer were used. Stabilization was performed using the Mul-lingan belt. Descriptive statistics were performed for characterization of the sample. To determine the validity of the MST with fixed stabilization, comparing it with the portable dynamometer, we investigated the correlation between the measurements obtained with the two instruments using the Pearson correlation coefficient. Intraclass Correlation Coefficient (ICC) was used to investigate inter-examiner and test-retest reliability (a = 0.05). Results: 59 individuals were included (1176 evaluations). A statistically significant correlation of moderate to high magnitude (0.58 < r < 0.81) was observed for concurrent validity of the MST with fixed stabilization versus the portable dynamometer for all muscle groups. Regarding inter-rater reliability, it was observed statistically significant ICC considered excellent to good (0.72 < r < 0.94) for all muscle groups. Regarding test-retest reliability, first evaluator presented good to excellent ICC (0.64 < r < 0.94), while second evaluator presented good to excellent ICC (0.74 < r < 0.96) for all muscle groups. Conclusion: The MST with fixed stabilization is valid and reliable for clinical measurement of muscle strength and can overcome previous limitations reported in the literature.
机译:目的:探讨改进的血压计试验(MST)的同步有效性,与便携式测功机相比,固定稳定性,并验证其测试 - 重新测试和互补性。方法:方法研究。测量以下基团的肌肉强度:髋部和膝关节和跖屈的腕部的屈肌和延伸部。使用TYCOS肺血压计和微耦合器2测功机。使用Mul-Lingan带进行稳定化。对样品表征进行描述性统计。为了确定具有固定稳定的MST的有效性,将其与便携式测功机进行比较,我们研究了使用Pearson相关系数与两个仪器获得的测量之间的相关性。胃内相关系数(ICC)用于研究检查互连和测试 - 保持可靠性(a = 0.05)。结果:包括59个个体(1176个评估)。对于具有固定稳定的MST的同时有效性,观察到中度至高幅度(0.58

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号