首页> 外文期刊>Journal of applied physiology >Sampling frequency affects the processing of Actigraph raw acceleration data to activity counts
【24h】

Sampling frequency affects the processing of Actigraph raw acceleration data to activity counts

机译:采样频率会影响Actigraph原始加速度数据的处理到活动计数

获取原文
获取原文并翻译 | 示例
           

摘要

ActiGraph acceleration data are processed through several steps (including band-pass filtering to attenuate unwanted signal frequencies) to generate the activity counts commonly used in physical activity research. We performed three experiments to investigate the effect of sampling frequency on the generation of activity counts. Ideal acceleration signals were produced in the MATLAB software. Thereafter, ActiGraph GT3X+ monitors were spun in a mechanical setup. Finally, 20 subjects performed walking and running wearing GT3X+ monitors. Acceleration data from all experiments were collected with different sampling frequencies, and activity counts were generated with the ActiLife software. With the default 30-Hz (or 60-Hz, 90-Hz) sampling frequency, the generation of activity counts was performed as intended with 50% attenuation of acceleration signals with a frequency of 2.5 Hz by the signal frequency band-pass filter. Frequencies above 5 Hz were eliminated totally. However, with other sampling frequencies, acceleration signals above 5 Hz escaped the band-pass filter to a varied degree and contributed to additional activity counts. Similar results were found for the spinning of the GT3X+ monitors, although the amount of activity counts generated was less, indicating that raw data stored in the GT3X+ monitor is processed. Between 600 and 1,600 more counts per minute were generated with the sampling frequencies 40 and 100 Hz compared with 30 Hz during running. Sampling frequency affects the processing of ActiGraph acceleration data to activity counts. Researchers need to be aware of this error when selecting sampling frequencies other than the default 30 Hz.
机译:Actigaph加速度数据通过几个步骤(包括带通滤波以衰减不需要的信号频率)来处理,以产生体育活动研究中常用的活动计数。我们进行了三个实验,以研究采样频率对活动计数产生的影响。在MATLAB软件中产生了理想的加速信号。此后,Actigraph Gt3x +显示器在机械设置中旋转。最后,20名科目行走,携带GT3X +监视器。来自所有实验的加速数据采用不同的采样频率收集,并使用Actilife软件产生活动计数。利用默认的30-Hz(或60-Hz,90-Hz)采样频率,按照信号频率带通滤波器的频率为2.5Hz的加速信号的50%衰减进行活动计数的产生。完全消除了5 Hz以上的频率。然而,对于其他采样频率,5Hz以上的加速信号逃离了带通滤波器到多大程度并导致额外的活动计数。发现类似的结果用于GT3X +监视器的纺丝,尽管产生的活动计数较少,表明处理了存储在GT3X +监视器中的原始数据。在跑步期间,使用采样频率40和100Hz产生600至1,600次,并产生每分钟40和100 Hz。采样频率会影响Actigraph加速度数据的处理到活动计数。在选择除默认30 Hz以外的采样频率时,研究人员需要了解此错误。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号