首页> 外文期刊>Journal of applied physiology >Sampling frequency affects the processing of Actigraph raw acceleration data to activity counts
【24h】

Sampling frequency affects the processing of Actigraph raw acceleration data to activity counts

机译:采样频率影响Actigraph原始加速度数据到活动计数的处理

获取原文
获取原文并翻译 | 示例
           

摘要

ActiGraph acceleration data are processed through several steps (including band-pass filtering to attenuate unwanted signal frequencies) to generate the activity counts commonly used in physical activity research. We performed three experiments to investigate the effect of sampling frequency on the generation of activity counts. Ideal acceleration signals were produced in the MATLAB software. Thereafter, ActiGraph GT3X + monitors were spun in a mechanical setup. Finally, 20 subjects performed walking and running wearing GT3X + monitors. Acceleration data from all experiments were collected with different sampling frequencies, and activity counts were generated with the ActiLife software. With the default 30-Hz (or 60-Hz, 90-Hz) sampling frequency, the generation of activity counts was performed as intended with 50% attenuation of acceleration signals with a frequency of 2.5 Hz by the signal frequency band-pass filter. Frequencies above 5 Hz were eliminated totally. However, with other sampling frequencies, acceleration signals above 5 Hz escaped the band-pass filter to a varied degree and contributed to additional activity counts. Similar results were found for the spinning of the GT3X + monitors, although the amount of activity counts generated was less, indicating that raw data stored in the GT3X + monitor is processed. Between 600 and 1,600 more counts per minute were generated with the sampling frequencies 40 and 100 Hz compared with 30 Hz during running. Sampling frequency affects the processing of ActiGraph acceleration data to activity counts. Researchers need to be aware of this error when selecting sampling frequencies other than the default 30 Hz.
机译:ActiGraph加速度数据通过几个步骤进行处理(包括通过带通滤波以衰减不想要的信号频率),以生成物理活动研究中常用的活动计数。我们进行了三个实验,以调查采样频率对活动计数生成的影响。在MATLAB软件中产生了理想的加速度信号。之后,以机械设置旋转ActiGraph GT3X +监视器。最后,有20名受试者穿着GT3X +显示器进行了步行和跑步。使用不同的采样频率收集所有实验的加速度数据,并使用ActiLife软件生成活动计数。在默认的30 Hz(或60 Hz,90 Hz)采样频率下,信号计数带通滤波器按预期执行活动计数的生成,并以2.5 Hz的频率衰减了加速度信号的50%。完全消除了5 Hz以上的频率。但是,在其他采样频率下,高于5 Hz的加速度信号在不同程度上逃脱了带通滤波器,并导致了额外的活动计数。对于GT3X +监视器的旋转,发现了相似的结果,尽管生成的活动计数较少,这表明处理了存储在GT3X +监视器中的原始数据。在40和100 Hz的采样频率下,每分钟产生600到1600个计数,而在运行期间则为30 Hz。采样频率会影响ActiGraph加速度数据对活动计数的处理。研究人员在选择默认的30 Hz以外的采样频率时需要注意此错误。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号