Abstract Purpose To optimize and evaluate an ultra-low-dose (ULD) technique for CT coronary angiography (CTCA). Materials and methods Eighty-two patients were randomly divided into two groups. ULD and routine CTCA were performed in groups A and B. Image quality, radiation dose and contrast agent were evaluated. Results The effective dose (ED) was 0.20?±?0.01?mSv for the ULD technique, a decrease of 87% ( t ?=???21.182, P ? t ?=???73.458, P ? χ 2 ?=?0.727, P ?=?0.394). The contrast-to-noise ratio was 19.31?±?7.95 for group A and 20.73?±?5.07 for group B: the difference was not statistically significant ( t ?=???1.678, P ?=?0.095). Conclusion Using an ultra-low radiation dose and contrast agent technique, while maintaining an assessable image and improving the safety of the medical examination, was a feasible and reliable method for CTCA.
机译:摘要目的,用于优化和评价CT冠状动脉造影(CTCA)的超低剂量(ULD)技术。 材料和方法82名患者随机分为两组。 在A和B组中进行ULD和常规CTCA。评估图像质量,辐射剂量和造影剂。 结果有效剂量(ED)为0.20≤0.20.201?MSV为ULD技术,降低87%(T?= ??? 21.182,p?t?= ??? 73.458,p?χ2?= ?0.727,p?= 0.394)。 对比度为19.31〜7.95,对于A组和20.73〜20.73α?5.07对于B组:差异没有统计学意义(T?= ??? 1.678,P?= 0.095)。 结论采用超低辐射剂量和造影剂技术,同时保持评估的图像和提高体检的安全性,是CTCA可行和可靠的方法。