首页> 外文期刊>Disability and rehabilitation. Assistive technology. >Long-term clinical evaluation of the automatic stance-phase lock-controlled prosthetic knee joint in young adults with unilateral above-knee amputation
【24h】

Long-term clinical evaluation of the automatic stance-phase lock-controlled prosthetic knee joint in young adults with unilateral above-knee amputation

机译:长期临床评价在膝关节外膝关节的年轻成年人中的自动阶段锁控假体膝关节

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: The purpose of this study was to clinically evaluate the automatic stance-phase lock (ASPL) knee mechanism against participants' existing weight-activated braking (WAB) prosthetic knee joint. Method: This prospective crossover study involved 10 young adults with an above-knee amputation. Primary measurements consisted of tests of walking speeds and capacity. Heart rate was measured during the six-minute walk test and the Physiological Cost Index (PCI) which was calculated from heart rate estimated energy expenditure. Activity was measured with a pedometer. User function and quality of life were assessed using the Lower Limb Function Questionnaire (LLFQ) and Prosthetic Evaluation Questionnaire (PEQ). Long-term follow-up over 12 months were completed. Results: Walking speeds were the same for WAB and APSL knees. Energy expenditure (PCI) was lower for the ASPL knees (p = 0.007). Step counts were the same for both knees, and questionnaires indicated ASPL knee preference attributed primarily to knee stability and improved walking, while limitations included terminal impact noise. Nine of 10 participants chose to keep using the ASPL knee as part of the long-term follow-up.Conclusions: Potential benefits of the ASPL knee were identified in this study by functional measures, questionnaires and user feedback, but not changes in activity or the PEQ.
机译:目的:本研究的目的是临床评估对参与者现有的重量激活制动(WAB)假体膝关节的自动静态相锁(ASPL)膝关节机制。方法:这项前瞻性交叉研究涉及10名年轻成年人,具有膝关节截肢。主要测量由步行速度和容量的测试组成。在六分钟的步行试验和生理成本指数(PCI)期间测量了心率,这些指数(PCI)是由心率估计能源支出计算的。用计步器测量活性。使用下肢功能调查问卷(LLFQ)和假体评估问卷(PEQ)评估用户功能和生活质量。长期随访12个月完成。结果:WAB和APSL膝盖的步行速度相同。 ASPL膝盖的能源支出(PCI)较低(P = 0.007)。膝盖的步骤数是相同的,并且调查问卷指示ASPL膝关节偏好主要归因于膝关节稳定性并改善行走,而限制包括终端冲击噪声。九个参与者选择继续使用ASPL膝关节作为长期随访的一部分。结论:通过功能措施,问卷和用户反馈,但不发生变化或者活动或者活动中的潜在福利peq。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号