首页> 外文期刊>AJR: American Journal of Roentgenology : Including Diagnostic Radiology, Radiation Oncology, Nuclear Medicine, Ultrasonography and Related Basic Sciences >Low injection rate for 3D moving-table bolus-chase MR angiography: initial experience with 3-T imaging to allay venous contamination in the calf.
【24h】

Low injection rate for 3D moving-table bolus-chase MR angiography: initial experience with 3-T imaging to allay venous contamination in the calf.

机译:3D移动台大剂量MR血管造影的低注射速率:3-T成像减轻小腿静脉污染的初步经验。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: The purpose of this study was to evaluate the potential for improving the image quality of 3D bolus-chase peripheral MR angiography by injecting contrast medium at a slow rate. SUBJECTS AND METHODS: Using similar imaging parameters in all cases, we performed bolus-chase MR angiography of the abdominal and lower limb arteries of 80 patients. The injection protocol for 40 patients had three parts: 20 mL of gadopentetate dimeglumine at 2 mL/s, 8 mL of gadopentetate dimeglumine at 1 mL/s, and 20 mL of saline solution at 1 mL/s. For the other 40 patients, the injection protocol was 20 mL of gadopentetate dimeglumine at 1.2 mL/s, 8 mL of gadopentetate dimeglumine at 0.7 mL/s, and 20 mL of saline solution at 0.7 mL/s. Using independent Student's t tests between groups, we compared signal-to-noise and contrast-to-noise ratios in the abdomen and pelvis, the thigh, and the calf. Arterial visibility and venous contamination on 3D images of the calf were graded and compared. RESULTS: The lower injectionrate increased arterial visibility (p < 0.001), reduced venous contamination in the calf (p < 0.001), and increased the contrast-to-noise ratio in the calf (p < 0.001). At the upper levels, signal-to-noise and contrast-to-noise ratios did not differ between the two groups. CONCLUSION: At 3-T MRI, a lower injection rate may alleviate venous contamination and increase arterial visibility in the calf while signal-to-noise and contrast-to-noise ratios at higher levels are maintained.
机译:目的:本研究的目的是评估通过缓慢注入造影剂来改善3D大剂量大剂量外周MR血管造影成像质量的潜力。研究对象和方法:在所有病例中使用相似的成像参数,我们对80例患者的腹部和下肢动脉进行了大剂量MR血管造影。 40位患者的注射方案分为三个部分:以2 mL / s速度注入20毫升g戊二酸二聚亮氨酸,以1 mL / s速度注入8毫升ado酸戊二酯二聚亮氨酸和以1 mL / s注入20毫升盐水溶液。对于其他40名患者,注射方案为1.2 mL / s的20 mL g戊二酸二聚亮氨酸,0.7 mL / s的8 mL ado戊二酸二聚亮氨酸和20 mL的0.7 mL / s盐水溶液。使用两组之间的独立Student t检验,我们比较了腹部和骨盆,大腿和小腿的信噪比和对比度噪声比。对小腿的3D图像上的动脉可见性和静脉污染进行分级和比较。结果:较低的注射率增加了动脉的可见度(p <0.001),减少了小腿的静脉污染(p <0.001),并增加了小腿的对比噪声比(p <0.001)。在较高级别,两组之间的信噪比和对比度噪声比没有差异。结论:在3-T MRI中,较低的注射速率可以减轻小腿静脉的污染并增加动脉的可见度,同时保持较高水平的信噪比和对比噪声比。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号