Introduction: Metal-on-metal (MoM) hip arthroplasties have shown high clinical failure rates with many patients at risk for a revision and under surveillance for high metal ion concentrations. Implant wear releasing such ions is assumed to be a function of use, i.e. the patient's physical activity. This study aimed to assess whether habitual physical activity levels of MoM patients are correlated with metal ion concentrations and are higher in patients with high (at risk) than in patients with low (safe) metal ion concentrations. Methods: A cohort study was conducted of patients with any type of MoM hip prosthesis. Metal ion concentrations were determined using ICP-MS. Habitual physical activity of subjects was measured in daily living using an acceleration-based activity monitor. Outcome consisted of quantitative and qualitative activity parameters. Results: In total, 62 patients were included. Mean age at surgery was 60.8 +/- 9.3years and follow-up was 6.3 +/- 1.4years. Cobalt concentrations were highly elevated overall (112.4 +/- 137.9nmol/L) and significantly more in bilateral (184.8 +/- 106.5nmol/L) than in unilateral cases (87.8 +/- 139.4nmol/L). No correlations were found between physical activity parameters and metal ion concentrations. Subgroup analysis of patients with low versus high cobalt concentration showed no significant differences in habitual physical activity. Discussion: No correlation was found between physical activity levels and metal ion concentrations. Implant use by normal habitual activities of daily living seems not to influence metal ion concentrations.
机译:介绍:金属金属(MOM)髋关节关节塑化术对许多患者进行了高临床失败利率,该患者对高金属离子浓度的调节和监视。假设植入磨损释放这些离子是使用的函数,即患者的身体活动。本研究旨在评估MOM患者的习惯性身体活性水平是否与金属离子浓度相关,高(危险性)患者高于低(安全)金属离子浓度的患者。方法:对患有任何类型的妈妈髋关节假体进行群组研究。使用ICP-MS测定金属离子浓度。使用基于加速的活动监测器在日常生活中测量受试者的习惯性身体活动。结果包括定量和定性活动参数。结果:总共包括62名患者。手术的平均年龄为60.8 +/- 9.3年和随访时间为6.3 +/- 1.4年。钴浓度总体升高(112.4 +/- 137.9nmol / L),双侧(184.8 +/- 106.5nmol / L)明显多于单侧案例(87.8 +/- 139.4nmol / l)。物理活性参数和金属离子浓度之间没有发现相关性。低钴浓度患者的亚组分析表明习惯性身体活动中没有显着差异。讨论:物理活性水平与金属离子浓度之间没有发现相关性。植入物使用正常惯常活动日常生活似乎不影响金属离子浓度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号