Abstract Background Fibrin sealants are topical agents used to reduce perioperative blood loss; however, their efficacy in total hip arthroplasty (THA) remains uncertain. The purpose of this study was to determine if a fibrin sealant containing aprotinin as an antifibrinolytic agent, TISSEEL (Baxter, Deerfield, IL), reduces postoperative blood loss and transfusion during THA when compared with intravenous (IV) tranexamic acid (TXA) and control groups. Methods Three retrospective uniform cohorts of primary THA procedures were identified, from a prospectively maintained database: 1 group who received TISSEEL, 1 group who received 1 g IV TXA, and 1 group who received neither (control). There were 80 patients in each group. Outcome measures included the lowest measured hemoglobin during postoperative hospitalization, greatest decrease in hemoglobin from preoperative to postoperative values, and blood transfusion rates. Results The minimum postoperative hemoglobin level was significantly lower for TISSEEL patients compared with that of IV TXA patients ( P ?= .021) and no different when compared with that of control patients ( P ?= .134). Patients receiving fibrin sealant had a greater hemoglobin level decrease compared with that of IV TXA ( P ?= .029) and control ( P ?= .036). Postoperative transfusion rates were no different for the group receiving TISSEEL compared with those of control ( P ?= .375) and were statistically greater when compared with those of IV TXA ( P ?= .002). Conclusion TISSEEL fibrin sealant does not reduce postoperative blood loss or transfusions; however, IV TXA reduced postoperative transfusions compared with TISSEEL and control. Therefore, TXA is recommended to reduce perioperative blood loss, while, utilization of a fibrin sealant requires further refinements before being adopted for routine use in THA.
机译:摘要背景纤维蛋白密封剂是用于减少围手术期失血的局部剂;然而,它们在总髋关节关节成形术(THA)中的疗效仍然不确定。本研究的目的是确定含有抑素蛋白蛋白作为抗纤维蛋白蛋白的纤维蛋白密封剂,Tisseel(Baxter,Deerfield,IL),与静脉内(IV)Tran蛋白酸(TXA)和对照相比,在THA期间减少术后失血和输血团体。方法识别出初级THA程序的三个回顾性均匀队列,从一份前瞻性维持的数据库中确定:1个收到Tisseel的1组,1次获得1 G秒TXA的组,以及1组既不接受(控制)。每组有80名患者。结果措施包括术后住院期间最低测量的血红蛋白,从术前到术后价值和输血率最大的血红蛋白减少。结果TISSEEL患者与IV TXA患者(P?= .021)相比,术后最低血红蛋白水平显着降低,与对照患者(P?= .134)相比没有什么不同。接受纤维蛋白密封剂的患者具有更大的血红蛋白水平降低,与IV TXA(P?= .029)和对照(P?= .036)相比。与对照(P = = .375)相比,接受尖端的组没有不同的输血率没有什么不同(P?= .375),与IV TXA(p?= .002)相比,统计学上更大。结论Tisseel纤维蛋白密封剂不会减少术后失血或输血;然而,与Tisseel和对照相比,IV TXA降低了术后输血。因此,推荐TXA以减少围手术期失血,而纤维蛋白密封剂的利用需要进一步的改进,然后在THA中采用常规用途。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号