首页> 外文期刊>Blood coagulation & fibrinolysis: an international journal in haemostasis and thrombosis >Evaluation of von Willebrand factor activity in factor Vlll/von Willebrand factor concentrates with the automated von Willebrand factor: activity IL test
【24h】

Evaluation of von Willebrand factor activity in factor Vlll/von Willebrand factor concentrates with the automated von Willebrand factor: activity IL test

机译:使用自动的von Willebrand因子:IL活性测试评估因子Viii / von Willebrand因子中的von Willebrand因子活性

获取原文
获取原文并翻译 | 示例
       

摘要

The von Willebrand ristocetin cofactor assay is still the main cleared measurement test used to evaluate von Willebrand factor (vWF) activity in concentrate samples containing vWF. Although the assay's performance has been improved over the years, the test reliability is still affected by a high interassay and interlaboratory variability; moreover, it requires skilled technicians and significant time. An automated HemosIL vWF:activity test, already set up on plasma samples, was then applied to factor VIII/vWF concentrates to verify its suitability in routine analysis of concentrate samples. As first step precision, linearity and accuracy were assessed. Then, 40 commercial batches of a high purity factor VIII/vWF concentrate were examined with this new method. The Spearman's correlation between the results obtained with the HemosIL vWF:activity assay and vWF activities determined by established procedures was evaluated. Comparisons of the means between HemosIL vWF:activity and the other tests were calculated with the Wilcoxon and Bland-Altman tests. Validation study showed satisfying within-run and between-run precision values. Activities determined with HemosIL vWF:actiyity had good correlation with those determined as ristocetin cofactor, Imubind (vWFMmubind) and collagen-binding. Wilcoxon test, used to compare the means between the HemosIL vWF:activity and the other activity assessments, proved no significant variation with vWF:lmubind, but displayed a slight variation with von Willebrand ristocetin cofactor and von Willebrand factor: collagen-binding. This automated HemosIL vWF: activity test could be included in routine determination of vWF activity in concentrate samples and supports traditional von Willebrand ristocetin cofactor because it is reliable, reproducible and sensitive.
机译:von Willebrand ristocetin辅因子测定仍是用于评估含有vWF的精矿样品中von Willebrand因子(vWF)活性的主要清除测量测试。尽管多年来这些方法的性能已得到改善,但检验的可靠性仍然受到较高的测定间和实验室间变异性的影响。此外,它需要熟练的技术人员和大量时间。然后将已经在血浆样品上建立的自动HemosIL vWF:活性测试应用于凝血因子VIII / vWF浓缩液,以验证其在浓缩液样品常规分析中的适用性。作为第一步,评估线性和准确性。然后,用这种新方法检查了40个商业批次的高纯度因子VIII / vWF浓缩物。评估了通过HemosIL vWF:活性测定获得的结果与通过既定程序确定的vWF活性之间的Spearman相关性。用Wilcoxon和Bland-Altman检验计算出HemosIL vWF:activity与其他检验之间的均值比较。验证研究表明,令人满意的批内和批间精度值。用HemosIL vWF:活性确定的活性与以瑞斯托霉素辅助因子,Imubind(vWFMmubind)和胶原蛋白结合确定的活性具有良好的相关性。用于比较HemosIL vWF:活性和其他活性评估之间的均值的Wilcoxon检验证明vWF:lmubind没有明显变化,但von Willebrand ristocetin辅因子和von Willebrand因子:胶原蛋白结合显示出细微变化。这项自动的HemosIL vWF:活性测试可以包括在浓缩样品中vWF活性的常规测定中,并且由于其可靠,可重现和敏感,因此支持传统的von Willebrand ristocetin辅因子。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号