PurposeClinical outcome of TKA remains unsatisfactory in 20% of the cases. Navigation has added accuracy in terms of alignment, but has improved clinical outcome only in small series with gap-balanced techniques. Reason for that could be that conventional gap balanced TKA determines gaps in extension and 90 degrees of flexion only. Furthermore, measurement is only static. Therefore, the accuracy of a new dynamic navigation software which allows gap assessment throughout the entire range of motion was tested. The purpose of this study was to investigate the accuracy and reliability of dynamic gap testing during gap-balanced TKA.MethodsIn two different centres, a total of 65 TKA procedures were performed in a tibia-first, gap-balanced technique using a new CAS software. At the same and at different time points of surgery, two different surgeons performed gap measurement to provide inter-observer reliability data and repeated gap measurement to provide intra-observer reliability data. These gap measurements were performed throughout the entire ROM under dynamic stress testing to detect maximum gap values.ResultsCAS surgery was able to produce correct coronal alignment in 96.4% of the cases (within 3 degrees mechanical alignment). Both inter-observer and intra-observer reliabilities were excellent for gap values throughout the entire ROM. Inter-observer bias of deviation 0.05; 95% limits of agreement of -2.1 to +2.21mm. Intra-observer bias of deviation 0.09; 95% limits of agreement of -2.27 to +2.44mm.ConclusionsThis new CAS software in combination with the presented dynamic gap measurement provides accurate gap values and therefore facilitates balancing TKA. This technique works reproducibly for different surgeons and has proven robustness also for repeated measurements of any surgeon in this study.
机译:在20%的病例中,TKA的PurposeClick结果仍然不令人满意。导航在对准方面增加了准确性,但只有在小系列中具有改进的临床结果,具有间隙平衡技术。原因可能是传统的差距平衡TKA确定延伸的间隙和仅90度屈曲。此外,测量仅是静态的。因此,测试了允许在整个运动范围内进行间隙评估的新动态导航软件的准确性。本研究的目的是调查间隙平衡TKA中动态差距测试的准确性和可靠性。在两种不同中心中,共有65个TKA程序,使用新的CAS软件进行胫骨第一,间隙平衡技术进行。在同一和在不同的手术时间点,两个不同的外科医生执行了差距测量,以提供观察者间可靠性数据和重复间隙测量以提供观察室内的可靠性数据。在整个ROM下在动态应力测试下进行这些间隙测量以检测最大间隙值。培养型手术能够在96.4%的情况下产生正确的冠状对准(在3℃内机械对准范围内)。观察者间和观察者间的可靠性均在整个ROM中的间隙值非常出色。观察者间偏差0.05; -2.1至+ 2.21mm的95%的协议限制。观察者内偏差0.09; -2.27至+ 2.44mm的95%限制-2.27至+ 2.44mm。结合所示的动态差距测量的结合结合新的CAS软件提供了准确的间隙值,因此有助于平衡TKA。这种技术可重复使用不同的外科医生,并且还在本研究中的任何外科医生重复测量的稳健性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号