Accuracy and repeatability of single-pose calibration of inertial measurement units for whole-body motion analysis

机译:全身运动分析惯性测量单元单姿势校准的精度和可重复性

获取原文
获取原文并翻译 | 示例
           

摘要

Portable inertial measurement units (IMUs) are suitable for motion analysis outside the laboratory. However, IMUs depend on the calibration of each body segment to measure human movement. Different calibration approaches have been developed for simplicity of use or similarity to laboratory motion analysis, but they have not been extensively examined. The main objective of the study was to determine the accuracy and repeatability of two common single-pose calibrations (N-pose and T-pose) under different conditions of placement (self-placement and passive placement), as well as their similarity to laboratory analysis based on anatomical landmarks. A further aim of the study was to develop two additional single-pose calibrations (chair-pose and stool-pose) and determine their accuracy and repeatability. Postures and movements of 12 healthy participants were recorded simultaneously with a full-body IMU suit and an optoelectronic system as the criterion measure. Three repetitions of the T-pose and the N-pose were executed by self-placement and passive placement, and three repetitions of the chair-pose and stool-pose were also performed. Repeatability for each single-pose calibration showed an average intraclass correlation coefficient for all axes and joints between 0.90 and 0.94 and a standard error of measurement between 1.5 degrees and 2.1 degrees. The T-pose with passive placement is recommended to reduce longitudinal axis offset error and to increase similarity to laboratory motion analysis. Finally, the chair-pose obtained the least longitudinal axis offset error amongst the tested poses, which shows potential for IMU calibration. (C) 2017 Elsevier B.V. All rights reserved.
机译:便携式惯性测量单元(IMU)适用于实验室外的运动分析。然而,IMUS取决于每个车身段的校准以测量人类运动。为简单地使用不同的校准方法或与实验室运动分析的相似性,但它们尚未广泛检查。该研究的主要目的是在不同的放置条件下确定两个常见的单个校准(N-POSE和T-POSE)的准确性和可重复性(自我放置和被动放置),以及它们与实验室的相似性基于解剖标志的分析。该研究的进一步目的是开发两种额外的单姿势校准(椅子 - 姿势和粪便姿势)并确定其准确性和可重复性。 12个健康参与者的姿势和运动与全身IMU西装和光电系统同时记录,作为标准测量。通过自置和被动放置执行T姿势的三次重复,并且还执行了椅子姿势和粪便姿势的三次重复。每个单个姿势校准的可重复性显示了所有轴的平均腹部相关系数,以及0.90和0.94之间的接头,标准误差在1.5度和2.1度之间。建议使用被动放置的T型姿势以减小纵向轴偏移误差并增加与实验室运动分析的相似性。最后,椅子 - 姿势在测试的姿势中获得了最小的纵向轴偏移误差,这表示IMU校准的可能性。 (c)2017 Elsevier B.v.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号