首页> 外文期刊>Journal of Biomechanics >Sensor-to-body calibration procedure for clinical motion analysis of lower limb using magnetic and inertial measurement units
【24h】

Sensor-to-body calibration procedure for clinical motion analysis of lower limb using magnetic and inertial measurement units

机译:使用磁性和惯性测量单元对下肢临床运动分析的传感器到体校准程序

获取原文
获取原文并翻译 | 示例
           

摘要

Magnetic and Inertial measurement units (MIMUs) have become exceedingly popular for ambulatory human motion analysis during the past two decades. However, measuring anatomically meaningful segment and joint kinematics requires virtual alignment of the MIMU frame with the anatomical frame of its corresponding segment. Therefore, this paper presents a simple calibration procedure, based on MIMU readouts, to align the inertial frame of the MIMU with the anatomical frames, as recommended by ISB. The proposed calibration includes five seconds of quiet standing in a neutral posture followed by ten consecutive hip flexions/extensions. This procedure will independently calibrate MIMUs attached to the pelvis, thigh, shank, and foot. The accuracy and repeatability of the calibration procedure and the 3D joint angle estimation were validated against the gold standard motion capture system by an experimental study with ten able-bodied participants. The procedure showed high test-retest repeatability in aligning the MIMU frame with its corresponding anatomical frame, i.e., the helical angle between the MIMU and anatomical frames did not significantly differ between the test and retest sessions (except for thigh MIMU). Compared to previously introduced procedures, this procedure attained the highest inter participant repeatability (inter-participant coefficient of variations of the helical angle: 20.5-42.2%). Further, the proposed calibration would reduce the offset errors of the 3D joint angle estimation (up to 12.8 degrees on average) compared to joint angle estimation without calibration (up to 26.3 degrees on average). The proposed calibration enables MIMU to measure clinically meaningful gait kinematics. (C) 2019 Elsevier Ltd. All rights reserved.
机译:磁性和惯性测量单位(MIMUS)在过去二十年中对动态人类运动分析变得非常流行。然而,测量解剖学有意义的段和关节运动学需要MIMU帧的虚拟对准与其相应段的解剖框架。因此,本文介绍了一种基于MIMU读数的简单校准程序,以使MIMU与解剖帧的惯性帧对齐,如ISB的推荐。所提出的校准包括在中性姿势中的五秒钟,然后是十个连续的臀部屈曲/延伸。该程序将独立地校准附着在骨盆,大腿,柄和脚上的Mimus。通过具有十个能够拥有的十个能够体验的参与者的实验研究,校准程序和3D关节角度估计的准确性和可重复性与金标准运动捕获系统验证。该过程显示了高测试 - 保持最高的可重复性,以使MIMU帧与其相应的解剖框架对准,即MIMU和解剖帧之间的螺旋角度在测试和重保持会话之间没有显着不同(大腿MIMU除外)。与先前引入的程序相比,该程序达到了最高的参与者可重复性(螺旋角度的参与者变异系数:20.5-42.2%)。此外,与关节角度估计相比,所提出的校准将减少3D关节角度估计(平均直到12.8度)的偏移误差(平均最多26.3度)。建议的校准使MIMU能够测量临床有意义的步态运动学。 (c)2019年elestvier有限公司保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号