首页> 外文期刊>European radiology >Impact of iodine concentration and iodine delivery rate on contrast enhancement in coronary CT angiography: a randomized multicenter trial (CT-CON)
【24h】

Impact of iodine concentration and iodine delivery rate on contrast enhancement in coronary CT angiography: a randomized multicenter trial (CT-CON)

机译:碘浓度和碘递送率对冠状动脉CT血管造影对比增强的影响:随机多中心试验(CT-CON)

获取原文
获取原文并翻译 | 示例
           

摘要

Objective To compare the effect of contrast medium iodine concentration on contrast enhancement, heart rate, and injection pressure when injected at a constant iodine delivery rate in coronary CT angiography (CTA). Methods One thousand twenty-four patients scheduled for coronary CTA were prospectively randomized to receive one of four contrast media: iopromide 300 mg I/ml, iohexol 350 mg I/ml, iopromide 370 mg I/ml, or iomeprol 400 mg I/ml. Contrast media were delivered at an equivalent iodine delivery rate of 2.0 g I/s. Intracoronary attenuation was measured and compared (per vessel and per segment). Heart rate before and after contrast media injection was documented. Injection pressure was recorded (n = 403) during contrast medium injection and compared between groups. Results Intracoronary attenuation values were similar for the different contrast groups. The mean attenuation over all segments ranged between 384 HU for 350 mg I/ml and 395 HU for 400 mg I/ml (p = 0.079). Dose-length product (p = 0.8424), signal-to-noise ratio (all p > 0.05), time to peak (p = 0.324), and changes in heart rate (p = 0.974) were comparable between groups. The peak pressures differed: 197.4 psi for 300 mg I/ml (viscosity 4.6 mPa s), 229.8 psi for 350 mg I/ml (10.4 mPa s), 216.1 psi for 370 mg I/ml (9.5 mPa s), and 243.7 psi for 400 mg I/ml (12.6 mPa s) (p < 0.0001). Conclusion Intravascular attenuation and changes in heart rate are independent of iodine concentration when contrast media are injected at the same iodine delivery rate. Differences in injection pressures are associated with the viscosity of the contrast media.
机译:目的在冠状动脉CT血管造影(CTA)中以恒定碘输送率注入造影剂中碘浓度对对比增强,心率和注射压力的比较。方法预定冠状动脉CTA的一千二十四名患者预计是随机的四种造影剂:IOPROMIDE 300mg I / mL,IOHEXOL 350mg I / mL,IOPROMIDE 370mg I / mL,或Iomeprol 400mg I / mL 。以2.0g I / s的等同碘输送速率递送造影剂。测量和比较颅内衰减(每血管和每个区段)。记录了对比介质注射前后的心率。在造影剂中注射期间记录注射压力(n = 403)并在组之间进行比较。结果不同对比度基团的颅内衰减值类似。所有段的平均衰减范围为350mg I / ml和400mg I / ml的350mg,395 HU(P = 0.079)。剂量长度产品(p = 0.8424),信噪比(所有p> 0.05),峰值时间(p = 0.324),并且在组之间的心率变化(p = 0.974)。峰值压力不同:300mg I / ml(粘度4.6MPa S),350mg I / ml(10.4MPa S),216.1psi,370mg I / ml(9.5MPa)和243.7 PSI 400mg I / mL(12.6MPa S)(P <0.0001)。结论当以相同的碘递送率注射造影剂时,心率衰减和心率变化与碘浓度无关。注射压力的差异与造影剂的粘度相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号