首页> 外文期刊>Erdol Erdgas Kohle >Nutzung moderner Technologien und Konzepte in der Grossgasmessung
【24h】

Nutzung moderner Technologien und Konzepte in der Grossgasmessung

机译:在批发气体测量中使用现代技术和概念

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

At the present time in the field of the large gas measurements normally two meters are used,connected in series,which are based on different physical principles.These are the duty meter and the reference meter.Both meters should only have a low measurement uncertainty and should corre-spond to applicable legal regulations.This type of Installation makes it possible to use the advantages of redundancy and mutual monitoring.Usually before installation,the meters are checked and adjusted to a difference near"zero"on a high pressure calibration Station.In some cases immediately after installation in the plant unacceptable deviations between the meters can occur.This depends on the technological design of each Station.If the causes for this are not well-known or clearly identifiable,nowadays a renewed calibration of the meter usually has to be performed.This approach is very expensive and time-consuming.Also there is no guarantee for success,since the influences of the plant on the calibration Stands are lacking.Anotherpossibility exists in the use of an ad-ditional reference measurement,which cor-responds to the most current State of the art.These reference meters need to be high-pre-cisely examined,and if possible independent of external influences and stable over a long period of time.From VNG's point of view this article de-scribes the current State in the range of large gas measurement and the use of an 8-path ultrasonic meter in combination with a coriolismeter for investigating a custody transfer measurement.The two custody transfer meters had deviations of approxi-mately 0.8% in the process.The described approach is,according to the Station conditions,very economical since the meters do not have to be removed for error diagnostics and not taken out of opera-tion.Furthermore,we receive additional Information about the flow conditions of the Station.We have the possibility of determin-ing installation effects and other influences of the gas measurements.In addition to this,these results lead to the conclusion that in the future new possibili-ties concerning the calibration and the design of large gas measurements respectively become possible.
机译:目前,在当前大气测量领域,通常使用两米,串联连接,基于不同的物理原理。这些是占空比和参考仪表。仪表应该只有低测量的不确定性应该支持适用的法律规定。这种安装可以使用冗余和相互监测的优点。在安装前,仪表被检查并调整到高压校准站附近“零”附近的差异。在某些情况下,在安装后立即在植物之间安装仪之间的不可接受的偏差可能发生。这取决于每个站的技术设计。如果这不是众所周知的或清晰可识别的原因,则通常具有更新的校准要进行。这一方法非常昂贵且耗时。因此,由于植物对校准的影响,因此没有成功的保证缺乏离子站。在使用广告的参考测量时,存在于使用的ad-ditional参考测量,这是针对最新的最新状态的响应。这些参考表需要高度预先检查,如果可能的情况完全独立于外部在很长一段时间内影响和稳定。从VGG的角度来看,该物品在大气体测量范围内进行当前状态,以及与辅助电气表组合使用8路径超声计进行调查监管转移测量。两次监管转移仪在过程中具有约0.8%的偏差。所描述的方法是根据车站条件,自从仪表不必拆除仪表以进行错误诊断而不是从歌剧中取出的情况下非常经济-tion.furtimore,我们收到有关该车站流动条件的其他信息。我们有可能确定安装效果和气体测量的其他影响。此外为此,这些结果导致了结论,在未来的校准和大型气体测量的设计中的未来可能是可能的。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号