首页> 外文期刊>International Journal of Dentistry >Bone Texture Fractal Dimension Analysis of Ultrasound-Treated Bone around Implant Site: A Double-Blind Clinical Trial
【24h】

Bone Texture Fractal Dimension Analysis of Ultrasound-Treated Bone around Implant Site: A Double-Blind Clinical Trial

机译:植入部位外超声处理骨的骨纹理分形维数分析:双盲临床试验

获取原文
获取原文并翻译 | 示例
       

摘要

Objectives. To evaluate the efficacy of bone texture fractal dimension (FD) analysis method in predicting implant stability from intraoral periapical radiographs using two implant protocols. Materials and Methods. A double-blind clinical trial was conducted on 22 subjects who needed dental implants. The participants were randomized into two groups, the control group with standard implant protocol treatment and the intervention group with added low-intensity power ultrasound treatment (LIPUS) besides the standard implant protocol. The FD values of bone density were carried out on the mesial and distal sides of the implant on digital intraoral radiographs using the box-counting method. Both resonance frequency (RF) and fractal dimension (FD) were assessed in three time intervals: after surgery and before and after loading. Results. FD on both the mesial and distal sides serve as very good-to-excellent tests with high validity (ROC area exceeding 0.8) in predicting high implant stability (ISQ?≥?70). The mesial side measurements were consistently better than the distal side among the intervention groups. The optimum cutoff value for the FD-mesial side that predicts a highly stable implant (ISQ?≥?70) is ≥1.505. At this optimum cutoff value, the mesial side FD is associated with a perfect sensitivity (100%) and fairly high specificity (86.5%). Conclusion. The FD analysis could be recommended as an adjunctive quantitative method in prediction of the implant stability with very high sensitivity and specificity. This trial is registered with ISRCTN72648040.
机译:目标。用两种植入方案评价骨纹理分形尺寸(FD)分析方法从口内局部射线照相预测植入物稳定性的疗效。材料和方法。在需要牙科植入物的22个受试者上进行双盲临床试验。与标准植入方案除了标准植入方案之外,参与者随机分为两组,对照组,具有标准植入方案治疗的对照组和具有添加低强度功率超声处理(LIPU)的干预组。使用盒子计数方法对数码内射线照相植入物的介质和远侧侧进行骨密度的FD值。共振频率(RF)和分形维数(FD)两次进行三次评估:手术后和装载前后。结果。间谍侧面的FD在预测高植入物稳定性(ISQ≥10℃)时,界面和远端侧面都具有非常良好的测试(ROC区域超过0.8)。间隔侧测量比干预组中的远侧侧始终如一。预测高度稳定的植入物(ISQ≥10)的FD-MESial侧的最佳截止值≥1.505。在该最佳截止值下,间隙侧FD与完美的敏感性(100%)和相当高的特异性相关(86.5%)。结论。可以推荐FD分析作为预测植入物稳定性的辅助定量方法,具有非常高的敏感性和特异性。此试验在ISRCTN72648040中注册。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号