首页> 外文期刊>Iranian journal of radiation research : >Low kilo volt 'prospective ECG-triggering' vs.'retrospective ECG-gating' coronary CTA: comparison of image quality and radiation dose
【24h】

Low kilo volt 'prospective ECG-triggering' vs.'retrospective ECG-gating' coronary CTA: comparison of image quality and radiation dose

机译:低千伏伏“潜在心电图触发”与“回顾性ECG-Gating”冠状动脉CTA:图像质量和辐射剂量的比较

获取原文
获取原文并翻译 | 示例
           

摘要

Background: To compare image quality and radiation doses of low kilovolt (kV) "prospective ECG-triggering" (PT) and standard "retrospective ECG-gating" (RG) coronary computed tomography (CT) angiography. Materials and Methods: A total of 101 consecutive patients (76 males, 25 females; mean age: 55.44 ± 8.28 years) with low-to-intermediate risk status for coronary artery disease and with a body mass index (BMI) of <30 kg/m2 were prospectively included in the study. The images were acquired with a 64-detector (128-slice) CT using the tube current modulation technique. The PT CT technique (100 kV, heart rate [HR]<70) was applied in 59 patients, while the RG CT technique (120 kV, HR>=70-90) was applied in 42 patients. The study was approved by the ethics committee.
机译:背景:比较低千伏(KV)“潜在ECG触发”(PT)和标准“回顾性ECG-Gating”(RG)冠状动脉造影(CT)血管造影的图像质量和辐射剂量。 材料和方法:共有101名连续患者(76名男性,25名女性;意思是年龄:55.44±8.28岁),冠状动脉疾病的低对中等风险状态和<30千克的体重指数(BMI) / M2似先纳入该研究。 使用管电流调制技术用64检测器(128切片)CT获取图像。 在59名患者中施用Pt CT技术(100kV,心率[HR] <70),而在42例患者中施用RG CT技术(120kV,HR> = 70-90)。 该研究得到了伦理委员会的批准。